Programming (continued)
WIRING TYPE
DEVICE ACTION
TS -
This mode will attempt
to close the door from
any position except
when fully closed, or
when a Entrapment
Protection input is
present. The stop
button will recycle the
Timer-To-Close (TTC) at
any position. To disable
the TTC in this mode,
installation of a defeat
switch is required (see
wiring diagram).
Momentary contact to
open, close, and stop
with open override and
TTC. Every device that
Front panel
causes door to open,
buttons
including a reversing
(membrane)
device, activates the
and
TTC. Auxiliary controls
3-Button
can be connected to
Wall
open input to activate
Controller
the TTC. If the timer
has been activated, the
open button and radio
control can recycle
the timer. The TTC will
function from the Open
limit and Open mid
stop with this operating
mode type. Close Mid
Stop available but not
shown in table.
Compatible with
3-Button Station,
1-Button Station and 1
and 3-Button Remote
Control.
Monitored Entrapment
Protection (LMEP)
Device required.
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN
button is
Door closing
pressed
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE
Door opening
button is
pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle Door closes to the CLOSE limit
Operator at OPEN limit
Operator at CLOSE limit
STOP
Door opening
button is
pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle No change in state (Recycle TTC)
Operator at OPEN limit
Operator at CLOSE limit
OPEN
Door opening
button
is held
Door closing
(constant
pressure)
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE
Door opening
button
Door closing
is held
Door at Open Mid-Stop
(constant
pressure)
Door stopped during open or close cycle Door closes to the CLOSE limit
42
RESPONSE
No change in state (Recycle TTC)
Door opens to the OPEN limit or Mid-Stop
and activates TTC
No change in state
Door will auto reverse to OPEN limit or Mid-
Stop and activates TTC
Door opens to the OPEN limit and activates
TTC
Door opens to the OPEN limit or Mid-Stop
and activates TTC
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
No change in state (Recycle TTC)
No change in state
Door stops and activates TTC
Door stops and activates TTC
No change in state (Recycle TTC)
No change in state (Recycle & hold TTC)
Door opens to the OPEN limit (bypasses
Mid-Stop) and activates TTC
No change in state (bypasses Mid-Stop)
and activates TTC
Door will auto reverse to OPEN limit
(bypasses Mid-Stop) and activates TTC
Door opens to the OPEN limit and activates
TTC
Door opens to the OPEN limit (bypasses
Mid-Stop) and activates TTC
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit