LiftMaster MAXUM JDC Serie Manual De Instalación página 27

Operadores industriales de cc ejes de unión, elevador y carro de cc para puertas
Idiomas disponibles

Idiomas disponibles

Testing
Apply power to the operator. When power is applied to the operator, the LCD display will illuminate, relay A, relay B, and
the Timer Defeat.
Test all Entrapment Protection Devices
It is the responsibility of the specifier, purchaser, installer, and
property owner to ensure that, on completion, the installation of
the entrapment protection devices comply with all relevant federal,
state, and local codes and regulations.
TEST THE MONITORED LIGHT CURTAIN (IF
APPLICABLE)
1.
With the door in the full open position, press the close
button.
2.
While the door is closing, obstruct any of the light beams on the Monitored Light Curtain (the green LED on the
Monitored Light Curtain Receiver will blink when the light beam is obstructed). The door should stop and reverse.
TEST THE PHOTOELECTRIC SENSORS (IF APPLICABLE)
1.
Open the door.
2.
Place an obstruction in the path of the photoelectric sensors. The LMEP LED will blink on the logic board.
3.
Press and hold the CLOSE button. The door should not close.
4.
Remove the obstruction.
5.
Press and hold the CLOSE button. Door should close. If the LMEP is activated while closing, the door should
reverse.
TEST THE EDGE SENSORS (IF APPLICABLE)
1.
Open the door
2.
Place an obstruction in the path of the door.
3.
Press and release the CLOSE button. The door should stop and/or reverse.
4.
Remove the obstruction. Press and release the CLOSE button. The door should fully close.
Test Wall Controller Menu Access
1.
Press OPEN button. (The door should move in the open direction.)
2.
Press STOP button. (The door should stop.)
3.
Press and hold the CLOSE button. (The door should move in the close direction.)
4.
Release CLOSE button. Door should stop if in C2 or D1 mode. Door will reverse to full open position in E2 mode.
The door should continue closing in all other modes.
5.
Press STOP button. (The door should stop.)
Test Limit Adjustment
1.
Press OPEN button. (The door should open.)
2.
Allow the door to fully open.
3.
Press and hold the CLOSE button. (The door should close.)
4.
Allow the door to fully close.
5.
If the limits are not set properly, remove power and adjust limits (see "Set Limits" section).
NOTE: Door travel should stop when the OPEN or CLOSE limits are reached. If door drifting is occurring, spring tension
on the door.
To avoid SERIOUS personal INJURY or
DEATH:
Disconnect electric power BEFORE
performing ANY adjustments or
maintenance.
ALL maintenance MUST be performed
by an Authorized Service Technician.
27
 WARNING
loading