Xylem JABSCO 18680-1000 Manual De Instalación Y Funcionamiento página 2

Bomba de paleta rotatoria reversible de 12 v cc
Ocultar thumbs Ver también para JABSCO 18680-1000:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Reversible Rotary Vane Pump 12V DC
FEATURES
Body:
Rotor:
Vanes:
Seal:
Motor:
Ports:
Height:
Length:
Width:
Weight:
*Vectra is a registered trademark of Celanese Corporation
**Ryton is a registered trademark of Chevron Phillips Chemical Company LP
APPLICATIONS
The Jabsco Reversible Rotary Vane Pump is ideal for transferring
diesel fuel. It is self-priming to 3ft. (1m) and can pump against a
discharge head up to 20ft. (6m). With its integral on-off reversing
switch, it is ideal for moving fuel between port and starboard fuel
tanks.
INSTALLATION
The pump must be mounted in a dry location – the motor is not
waterproof and must not be submerged. SELECTION OF A COOL,
VENTILATED location will generally extend pump motor life. The
unit can be mounted in any desired position. It is best to mount
so that fluid dripping from a loose port connection will not wet
the motor. Motor with switch assembly meets USCG Electrical
Standards (Title 33, Chapter I, Part 183; Subpart I), and ISO 8846
Marine for IGNITION PROTECTION. SEE WARNING NOTE.
HEAD CAPACITY TABLE
PSI
2.1
4.3
6.5
8.7
Table shows approximate Head-Flow for new pump.
Bronze
Vectra*
Ryton**
Lip Type, Nitrile
12V DC Permanent magnet
Type, Intermittent Duty, Fully
Enclosed, IP44, Stainless
Steel Shaft
1⁄2" NPT Internal Pipe Threads
1" (25mm) External Hose Barb
3-3⁄8" (86mm)
8-5⁄8" (219mm)
4-3⁄4" (121mm)
5-1⁄2lbs (2.5 kg)
Total Head Feet
5
10
15
20
PLUMBING CONECTIONS
Pump ports have external 1" (25mm) hose barb and internal 1⁄2"
NPT pipe threads. Use hose that does not kink when bent and with
sufficient wall thickness to prevent collapse when used on suction
side of pump. Ideally, hoses should be routed so that some fluid
will be retained in pump body to wet the rotor and vanes. Wetting
the rotor and vanes aids priming. Use a strainer on the intake hose
if debris or solids are present in the fluid being pumped.
ALL HOSES MUST HAVE AIRTIGHT CONNECTIONS TO ENABLE FAST
PRIMING.
EXPLOSION HAZARD: Do not operate with
rivets removed from motor case. Explosion resulting
in personal injury, death or property damage can
occur. Case openings must be sealed to avoid
explosion and maintain ignition protected rating.
EXPLOSION HAZARD: Do not use Jabsco
pump for pumping gasoline or other flammable
liquids with flash point below 100°F (37.8°C). Doing
so may result in an explosion which could cause
personal injury, death or property damage.
Total Head Metres
1.5
3.0
4.6
6.1
2
Model 18680-1000
Capacity US GPM
5.2
5.0
4.7
4.3
Capacity LPM
19.7
18.9
17.8
16.3
loading