ENGLISH
Time modes settings
Holiday mode
Holidays duration time
Holiday Mode is useful when the user is away from the room for longer than a day.
Operation involves:
• Operation for 30 minutes at speed '2'.
• Thereafter the appliance operates at a speed 30% lower than speed 1.
3. Alarm control panel
This option is based on connecting the home alarm system (or a switch) to a digital input on the board. If a normally open
switch is installed, the logic state must be set to "Normally closed". When the home owner activates the alarm unit, or
operates the switch, the system detects that the home is empty and operates in two different modes:
• The appliance switches off if "Ventilation unit response" is set to "Switching off the panel".
• If "Ventilation unit response" is set to "Change of speed" instead, the appliance changes the operating speed of the
extraction and supply fans according to the set values.
When ventilation mode is activated, the fans run at a pre-set speed (50% in the example) for the time set in "Duration of
airing". For the remaining time, set under "Airing time cycle", the appliance will instead operate in the mode set under
"Ventilation unit response".
Alarm control panel
Alarm control panel enable
Input logic state
Ventilation unit response
Extraction fan control
Supply fan control
Airing
Airing
Supply fan control
Extraction fan control
Duration of airing
Airing time cycle
Operation of the secondary heater during airing
9.2.5 "Graph" button
By accessing the pop-up menu, from the "
values by means of curves (intake / exhaust / supply / extraction / geothermal heat exchanger) and the percentage value of
the supply and extraction fan over a given period of time.
58
Graph " button, it is possible to access the graph which shows the temperature
Yes
Normally clo...
Switching of...
50%
13%
100%
100%
13%
50%
Inactive
50%
13%
100%
50%
13%
100%
10min.
1min.
100min.
1h
1h
24h
Off