Trouble check
Picture
Symptom
Cause and/or corrective actions
The picture is "noisy" or does not appear.
* The video heads may be dirty.
% Clean the heads using the Sony DVM12CL (not
supplied) cleaning cassette. (p. 66)
€& indicator flashes on the TV screen.
* The video heads may be dirty.
- > Clean the heads using the Sony DVM12CL (not
supplied) cleaning cassette. (p. 66)
Others
Symptom
Cause and/or corrective actions
While editing using the DV connecting
* Remove the DV connecting cable, and connect it
cable, recording picture cannot be
again.
monitored.
The VCR becomes warm.
© If the power of the VCR is on for a long time, it
becomes warm, which is not malfunction.
No function works though the power is
¢ Disconnect the connecting plug on the AC adaptor/
on.
charger or the battery pack, then reconnect it in about
one minute. Turn the power on. If the functions still
do not work, press the RESET button at the bottom of
the VCR using a sharp-pointed object. (If you press
the RESET button, all the settings including the date
and time return to the factory setting.) (p. 82)
The numbers or letters of 5 characters is
¢ Self-diagnosis function was activated.
displayed as a counter.
> See the table in page 74 and treat the VCR
apropriately.
AC adaptor/charger
Symptom
Corrective actions
The VTR/CAMERA or CHARGE lamp
* Disconnect the power cord. After about one minute,
does not light.
reconnect the power cord. (p. 8)
The CHARGE lamp flashes.
© See the chart on the next page.