TABLE OF PIPE DIAMETERS ADVISED FORM MOUNTING TO INLET AND OUTLET
PUMP POWER
PUMP - PSP 3.5 HP
PUMP - PSP 4.5 HP
PUMP - PSP 5.5 HP
PUMP - PSP 7.5 HP
PUMP - PSP 10 HP
FLOW
SPEED
POWER CONNECTION
CAUTION — This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so
marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such
that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for
storage and reassembled to its original integrity.
CAUTION — To prevent possible voltage reduction that cause flicker sensations in lighting equipment, this product
should be powered by a dedicated power line capable of providing at least 32 A per phase. Other equipment connected to the
same power line may experience operation problems caused by the inrush current during start-up of this product.
WARNING — Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with all ap-
plicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious
injury to pool users, installers, or others due to electrical shock, and may also cause damage to property. Always disconnect
power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury
to serviceman, pool users or others due to electric shock.
•
Fill pump pre-filter and suction line completely with liquid.
•
Electric connections must done by a qualified technician and they must use approve cables by standards.
•
Ensure that the electrical service is disconnected, properly tagged and locked out before working on the pump.
•
The power supply cable must be laid in such a way that it never touches the pipework, pump or motor casing
•
Check voltage, phase and frequency on motor nameplate.
•
The electric motor must be protected against overloading by means of circuit breakers and fuses.
breakers and fuses must be selected in accordance with full load amperage of the motor appearing on the motor rating
plate. A motor guard with magneto-thermal protection must be used.
•
Prior to connecting the electrical wiring rotate shaft by hand to make sure rotor rotates easily.
•
Connect the electrical wiring in accordance with local electrical codes and make sure to ground the motor. A grounding
conductor does not carry current so neutral is not a ground.
•
The connection diagram can be found in the terminal box of the motor or below in the instruction manual.
•
The main connection on the tag board depends on the nominal power of the motor, the power supply and the type of
connection.
•
The necessary connection of the bridges in the terminal box is shown in the following.
G-INSB-PSP (REV 02/2013)
SUCTION LINE
PIPE DIAMETER
2850 RPM
110 mm
125 mm
140 mm
160 mm
200 mm
Suction Line
Discharge Line
1.5% Sloping Line
Collector
DISCHARGE LINE
PIPE DIAMETER
90 mm
110 mm
110 mm
125 mm
160 mm
V=1.50 m/sn
V=2.50 m/sn
V=0.75 m/sn
V= 0.50 m/sn
C i r c u i t
6