Oase AquaMax Eco Classic Serie Instrucciones De Uso página 35

Ocultar thumbs Ver también para AquaMax Eco Classic Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
Replacing the impeller unit
NOTE
The impeller unit contains strong magnets that attract magnetic particles (e.g. iron filings). Any
remaining particles can cause irreparable damage to the impeller unit and motor block.
Carefully remove any adhering particles from the impeller unit prior to installation.
• Dismantle the motor block as shown in the figure.
• Use a brush under clear water to clean the components.
• Check all components for damage. Replace damaged or worn components.
• Reassemble the motor block in reverse order.
Storage/winter protection
Shut down the unit at water temperatures below +4 °C or at the latest when freezing tempera-
tures are expected.
• Thoroughly clean the unit.
• Check the unit for damage and replace damaged components.
• Store the pump immersed in water or filled with water in an environment protected against
freezing. Do not immerse the power plug in water!
EN
AMX0093
35
loading