Sicam SBM 60 Manual Original página 53

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
Faults
Causes
20
1. Pedal pressed during measurement
2. Irregular rotational speed of motor
3. Wheel speed below minimum value
21
The PCB has detected an excessively high wheel speed
with the wheel guard open (shaft rotating at high speed
although the machine has not been started): Power
supply unit is deactivated
22
Irregular measurement sensor signals
29
One electronic vernier caliper not in rest position.
30
Angular width gauge deactivated.
31
Pedal being pressed. Deactivation takes place.
32
Pedal has been pressed.
33
Incorrect operating system
34
Restart the system.
SICAM srl soc. Unip
Faults | SBM V85 A | 53
Remedy
1. Do not press pedal whilst motor is in operation.
2. Make sure the SBM V85 A is not subjected to
any impact during measurement.
3. Check mains voltage (probably too low).
1. Switch off the SBM V85 A .
2. Lower the wheel guard, switch the SBM V85 A
on again without moving the wheel.
3. If the error message persists, contact customer
service.
1. Check that the light barrier PCB is protected
against light and provide a cover if necessary.
2. Check and if necessary replace the light barrier
PCB.
3. Check and if necessary replace the display PCB.
1. Set electronic vernier caliper to rest position.
2. Repeat calibration of electronic vernier caliper.
Perform calibration prior to reactivation.
1. Avoid pressing the pedal during measuring cycle;
2. Check correct functioning of the pedal micro
switch.
1. Avoid pressing the pedal during measuring cycle;
2. Check correct functioning of the pedal micro
switch.
Use a different PCB.
1 695 600 571