5 OPERATION
5.3.2
Setting a welding procedure
Quick set-up procedure
1. For Constant Voltage (CV) Power Source; Set the desired arc voltage on the power
source.
2. For Constant Current (CC) Power Source; Set the desired weld current on the power
source.
3. On the MobileFeed unit: Set the desired wire feed speed with the knob for the wire feed
speed and use the values shown by the display as guidance.
A feeder in CV mode will show the actual wire feed speed while welding.
A feeder in CC mode will show a wire feed speed that varies with changes in arc voltage.
When not welding, the display will show what the wire feed speed will be at the displayed
voltage.
5.3.3
Weld data table
The voltage (V) and current (A) values presented in the tables below are the arc voltage and
the weld current. Values of current (A) that may flow through the wire feeder may not be
higher than rated values of the unit.
Flux Core E70T-1 & 2
Diameter
150 /
200 /
3.8
5.1
.045"
29 V
150 A
.052"
25 V
155 A
1/16"
27 V
190 A
Metal Core
Diameter
200 / 5.1
.045"
.052"
1/16"
30 V
300 V
Steel Solid Wire
Diameter
200 /
250 /
5.1
6.35
.035"
0558 012 630
Wire Feed Speed
(inch/min) / (m/min)
250 /
300 /
6.35
7.6
29 V
210 A
30 V
300 A
30 V
33 V
300 A
365 A
Wire Feed Speed
(inch/min) / (m/min)
250 / 6.35 300 / 7.6
28 V
250 A
29 V
29 V
275 A
300 A
30 V
32 V
350 A
400 A
Wire Feed Speed
(inch/min) / (m/min)
300 /
350 /
7.6
8.9
- 20 -
350 /
400 /
450 /
8.9
10.2
11.4
30 V
250 A
33 V
410 A
350 / 8.9
400 / 10.2 450 / 11.4 500 / 12.7
29 V
30 V
260 A
270 A
30 V
325 A
400 /
450 /
500 /
10.2
11.4
12.7
25 V
25 V
26 V
180 A
200 A
215 A
500 /
600 /
12.7
15.2
33 V
34 V
290 A
330 A
32 V
32 V
300 A
350 A
550 /
600 /
14.0
15.2
27 V
28 V
230 A
245 A
© ESAB AB 2015