Check power level
Test emergency stop and belly button
Lubricate lubrication points
Tighten guide balls
Tighten wheels
Oil
When changing hydraulic oil, use 832 WRHV. The oil level is checked with the oil indicator. There must be between
5-10 millimeters of oil on the indicator. The oil indicator is attached under the lid. At empty tank add 2 liters of new oil.
When filling gear oil use 80W90. When changing empty the gear and then add 0.3 liters of new oil.
Troubleshooting
In the event of a machine error an error code will appear on the machine's LED Display. The list of error codes
and their meaning is only available in English and can be found at the back of the operations manual.
If in doubt, contact your dealer or Twinca A/S.
In the event of damage to the hydraulics or the wiring harness, a drawing of these can be found in the maintenance
instructions. Repair and maintenance of these parts is recommended to be performed only by the dealer where
the machine was purchased or by other specialized personnel with a relevant craftsman background who possess
the maintenance instructions.
WARNING: When repairing and maintaining the electrical parts of the machine, the machine must be turned
off and the batteries removed. There is a risk of getting shocked.
Cleaning the machine
The chassis and dump bed can be rinsed with an ordinary garden hose with low pressure. If necessary, a soft brush
can be used. The control handle must only be wiped over with a damp cloth and not exposed to direct water spray.
It is not permitted to use a high-pressure cleaner or anything else that could damage the machine and its electrical
parts.
Cleaning of the engine room should only be done with air pressure. In-depth cleaning of parts is described in the
TWINCAES5008001-EN
46