FLASH
FAULT NAME
CODE
0X9A
Interlock Braking
Supervision
0X9B
EMR Supervision
0XA1
Driver 1 Fault
0XA2
Driver 2 Fault
0XA3
Driver 3 Fault
Twinca A/S | Nr. Bjertvej 14 | DK-7830 Vinderup | CVR nr: 25 80 49 29 |
[email protected] | Tlf: +45 97 44 85 55 | www.twincadumper.com | www.twinca.dk
POSSIBLE CAUSES
1. During an interlock braking
event, the motor speed exceeded
the limit set by the Interlock
Braking Supervision parameters.
2. See Programmer » Application
Setup » Interlock Braking »
Supervision Enable.
3. See Programmer » Application
Setup » Interlock Braking »
Interlock Braking Supervision.
1. During an EMR event, the motor
speed exceeded the limit set by the
Emergency Reverse Supervision
parameters.
2. See Programmer » Application
Setup » Emergency Reverse »
Emergency Reverse Supervision.
1. Open or short on driver load.
2. Dirty connector pins at controller
or contactor coil.
3. Bad connector crimps or faulty
wiring.
4. Driver overcurrent, as set by the
Driver 1 Overcurrent parameter.
5. See Programmer » Controller
Setup » Outputs » Driver 1 » Driver
1 Overcurrent.
1. Open or short on driver load.
2. Dirty connector pins at controller
or contactor coil.
3. Bad connector crimps or faulty
wiring.
4. Driver overcurrent, as set by the
Driver 2 Overcurrent parameter.
5. See Programmer » Controller
Setup » Outputs » Driver 2 » Driver
2 Overcurrent.
1. Open or short on driver load.
2. Dirty connector pins at controller
or contactor coil.
3. Bad connector crimps or faulty
wiring.
4. Driver overcurrent, as set by the
Driver 3 Overcurrent parameter.
5. See Programmer » Controller
Setup » Outputs » Driver 3 » Driver
3 Overcurrent.
283
SET/CLEAR CONDITIONS
Set: During an interlock bra-
king event, the motor speed
exceeded the limit set by the
Interlock Braking Supervision
parameters.
Clear: Reset Controller.
Set: During an interlock
braking event, the motor
speed exceeded the limit set
by the Emergency Reverse
Supervision parameters.
Clear: Reset Controller.
Set: Driver 1 is either open or
shorted. Or Driver 1 exceeded
its overcurrent setting.
Clear: Correct open or short,
and then Reset Controller.
Set: Driver 2 is either open or
shorted. Or Driver 2 exceeded
its overcurrent setting.
Clear: Correct open or short,
and then Reset Controller.
Set: Driver 3 is either open or
shorted. Or Driver 3 exceeded
its overcurrent setting.
Clear: Correct open or short,
and then Reset Controller.