Cleaning the Hel-X bio-elements
The best time to clean soiled Hel-X bio-elements is when the filter fleece is used up and no longer co-
vers the drum. (→ Changing the filter fleece)
 Switch off the filter pump.
 Turn the drum by hand to wash the Hel-X bio-elements in the container water.
 If necessary, support cleaning with a water jet.
 Drain the water in the container via the dirt outlet after cleaning.
ClearWaveRemoving and cleaning filter elements
The filter micro-organisms colonise the surface of the ClearWave filter elements. These deposits are
desired. For this reason only clean the ClearWave filter elements in the event of severe clogging.
When the container is cleaned, the filter elements can be removed and hosed off with a powerful wa-
ter jet. (→ Regular tasks)
ProfiClear Premium Fleece 500
How to proceed:
1. Remove the cap nuts M6 on both sides in the container and remove the holders.
2. Remove the ClearWave filter elements.
3. Install the ClearWave filter elements in reverse order.
– Ensure that the filter elements are correctly positioned in the holders at the bottom of the
container.