Hitachi NV 83A4 Instrucciones Y Manual De Seguridad página 13

Idiomas disponibles

Idiomas disponibles

Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
LOADING NAILS
● When loading nails into Nailer,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
(1) Grip the nail guide and knob with fi nger.
Press the knob down and swing the nail guide open.
And open the magazine cover.
Knob
Nail guide
(2) Adjust the position of the plate according to the nail
length.
The nail will not feed smoothly if the plate is not
correctly adjusted.
Magazine
Nail holder
NOTE: Before loading nails in the magazine, adjust
the plate. If the magazine cover is forcibly
closed without adjusting the plate correctly,
the nail holder may be damaged.
WARNING
Magazine cover
Magazine cover
1 Turn the nail holder about 90 degrees
)
counterclockwise.
2
2 Slide in vertical direction possible.
Lift or lower the nail holder to accept diff erent
length nails.
3 Adjust the plate to the nail length reference points
on the magazine cover and turn the nail holder 90
degrees clockwise until you hear "click".
2"
1
3
2
/
" 2
/
"
4
8
1
3
2
/
" 2
/
"
2
4
1
3" 3
/
"
4
Magazine
(3) Place the nail coil into the magazine.
Uncoil enough nails to reach the driving hole.
Magazine
(4) 1 Uncoil enough nails to reach the driving hole.
2 Insert the fi rst nail into the driving hole and the
second nail between the two pawls of the feeder.
3 Fit the nail heads in the guide slot.
Driving hole Guide slot
First nail
Nail Guide
4 Pulling the nails to the right, swing the nail guide
closed.
English
2
1
3
Nail holder
Nail holder
Nails
3
2
Guide surface
2
Feeder
4
1
13