It is the law that all gas appliances are installed by competent persons in accordance with
the current edition of Gas Safety Installation and Use Regulations.
It is in your interest and that of safety to ensure compliance with the law.
GAS SPECIFICATION
GAS TYPE AND PRESSURE
G30 29 mbar
G20 20 mbar
ELECTRICAL CONNECTION:
This appliance must be earthed.
This appliance is design ed to be connected to a 220-240 V, 50-60 Hz electricity supply.
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow → Earth
-
Blue → Neutral
-
Brown → Live
-
The wire which is coloured green and yellow must be connected to the terminal which is
marked with the letter E or by the earth symbol.
WIRING DIAGRAM
HEAT INPUT AND ORIFICE SIZE MARKED (MM)
Wok burner
Rapid burner
3,3kW
(241g/h)
0,93
1,28
Semi-rapid
/
1,75 kW
(127 g/h)
/
0,66
/
1,00
Auxiliary - rapid
1,0 kW
(73 g/h)
0,50
0,78