3.4
System tester
3.4.1
Diagnosis panel
Fig. 1:
Diagnosis panel
1 OBD diagnostic cable connection (DIAG)
3.4.2
Connection panel
15V
Fig. 2:
Connection panel
1 Power supply unit connection
2 LED A and LED B (refer to Section 3.4.3)
3 USB connection
Robert Bosch GmbH
3.4.3
Status
KTS 515 ready for
operation
Data communication
DIAG
with the controller
Firmware update
in operation
459802_12-Ko
LED A
1
Does not
illuminate
Flashes green
(irregular)
Illuminated green
Illuminated red
LED B
Does not
illuminate
Flashes green
459908_01_We
(1 second
interval)
Illuminated green
Flashes yellow
(1 second
interval)
Illuminated
yellow
Flashes red
(irregular)
Illuminated red
*)
3.4.4
The adapter insert (fig. 3, item 4) contains all of the
existing capabilities for establishing communication
with the vehicle diagnosis interfaces that are known. In
order to flexibly adapt to future expansions in diagnosis
protocols, the adapter insert can be changed quickly
without any tools.
i
Description of unit | KTS 515 | 15 |
Functions of LEDs A and B
LED A
Does not
illuminate
Flashes green
(irregular)
Does not
illuminate
Function
No data
communication with
the controller
Data communication
with the controller
Fault in hardware/
Firmware
Power supply
> 35 Volt.
Function
Voltage not present
KTS 515 ready for
operation
Fault in hardware/
Firmware
Overvoltage on
diagnostic cable
Fault in hardware/
Firmware
Firmware update
in operation
Fault in firmware-
update
Unplug the USB connection and power supply and connect
them again. If the error still exists, contact customer service.
Adapter insert (IBOX 01)
KTS modules only function with the adapter insert
connected.
en
LED B
Flashes green
(1 second interval)
Flashes green
(1 second interval)
Flashes red
(irregular)
Measures
Check connection
with the controller
None
*)
Check voltage in
vehicle
Measures
Check power
supply
None
*)
*)
*)
None
Repeat firmware
update
|