Zodiac Z350iQ Serie Manual De Instrucciones página 4

Prioridad calefacción
Ocultar thumbs Ver también para Z350iQ Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
4.
Once D06 is connected, you will be able to use heating priority using following logic:
Connect the filtration pump to the heat pump (= activate the heating priority) to force the filtration to operate if hte water
is not at the desired temperature.
When heating priority is activated:
If heating is needed, the heat pump will for the filtration pump to run even thgouth it is outside its filtration hours
to maintain the pool water temperature.
If heating is not needed:
o
And filtration is inside its running hours – the filtration pump will continue to run without the heat pump.
o
And filtration is outside its running hours – the filtration pump will not run.
Make sure that the electricity supply has been switched off.
Connect a 230V/dry contact relay (not included) to terminals 1 and 2 (230 V output), then connect the connection
cable (not included) from the output of this relay to the filtration timer as shown in the diagram.
The "heaing priority" function is deactivated by default. To activate it, set the P50 parameter to "ON".
A dry contact relay is needed because power of the filtration pump must be independant from Z350 mainboard.
Part included:
Finder relay RSB 46.52.8.230.0040
DIN socket: 97.02 (blue)
A1 – A2: Power for the filter pump power
contractor evaporator
B: Filtration timer
C: Power contactor (two-pole contactor)
for the filter pump motor
D: Separate connecting cable for the
"heating priority" function (no included)
E: Heat pump terminal (230 V output)
F: Fuse
G: 230V/dry contact relay (not included)
4