device gives the machine time to return to its normal operating temperature. The value of this command is
preset at 60 min. but can be varied from 30 to 360 min.
N.B.: with the SLAVE SPIRALS enabled (see command 49), after setting the MASTER machine, access is
given for setting the same parameters for the SLAVE machine.
Option available only on MEGACOLD L SLAVE vending machines.
Command 46 Setting fridge safety temperature:
This command sets the temperature at which the safety device is triggered off, i.e. the temperature above
which the selection of products is blocked (see Command 48). The display visualises an appropriate warning
message when you try to obtain a product from these selections. The control is inhibited on switching on and
after closing the door for the time set on command 45. The default value is +7°C but it can vary from +7°C to
+35°C. When the fridge safety device is triggered off, the selections concerned remain out of service. To
restore fridge safety: with the door open, the display of the master vending machine visualises the block on
the master or possibly on the slaves connected to the master. The function is restored by pressing the
ENTER key on the external button board. By pressing the ESC key or by re-closing the door, the safety
device continues to block functioning and is registered as ERROR 93. If the fridge safety device is still active
when the door is closed, an acoustic alarm will automatically ring (a series of BEEPS).
The products introduced must already be at the correct temperature indicated for
conservation by the provisions in force. Failure to observe this rule could cause the "fridge
safety" device to be triggered off.
see paragraph "PRODUCT LOADING WARNINGS"
N.B.: with the SLAVE SPIRALS enabled (see command 49), after setting the MASTER machine, access is
given for setting the same parameters for the SLAVE machine.
Option available only on MEGACOLD L SLAVE vending machines.
Command 48 Setting trays with refrigeration safety device:
This option is only available on MEGACOLD L SLAVE vending machines (see command 40)
This command allows you to select which trays are subject to the refrigeration safety device. The command
requires a setting for each tray: enable safety device = 1, or disable safety device = 0. Tray 1 refers to the top
tray. By default, all the trays are set at 1.
For the machine to function correctly the drawers to be set with the refrigeration unit safety
device
CHARACTERISTICS).
N.B.: with the SLAVE SPIRALS enabled (see command 49), after setting the MASTER machine, access is
given for setting the same parameters for the SLAVE machine.
Option available only on MEGACOLD L SLAVE vending machines.
9.2.3

TO SET MACHINE PARAMETERS

Command 49 Enable/disable slave spirals:
This command enables the master/slave connection. a slave snack machine can be connected.
Command 50 Machine configuration:
The system asks you to enter the number of the selections present in the machine. Every time the door is
closed, the system checks if the number of selections present in the machine corresponds to the set number.
If there is no connection to a selection or if a motor breaks down, the display visualises the indication of the
blocked selection.
N.B. Update this command if the machine is re-configured.
Command 55 Price display enable multifunction:
(if present)
To set the following option ONLY, you must press the "Programming Button" twice
consecutively, signalled by the sound of the buzzer, to access the second menu level.
The display shows "Command 00". To exit programming mode, press the button "ESC".