Installation - Saeco MEGACOLD L Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MEGACOLD L– Issue 01
6.3

INSTALLATION

The vending machine must be installed on a surface (floor, intermediate floor) of suitable bearing capacity.
The appliance is not suitable for external installation as it must not be exposed to direct
sunlight or be installed where water jets may be used. The appliance is suitable for
installation in locations where the ambient temperature ranges between 3°C and 32°C.
Check that the capacity of the plant is suitable for the vending machine's maximum power specified on the
data plate. If in doubt contact professionally qualified personnel. Such personnel should also verify that the
section of the plant cables are suitable for the power absorbed by the vending machine.
The appliance must be connected to a power supply mains featuring earthing which
complies with current legislation. The manufacturer recommends providing an electric
power supply mains for the vending machine which is equipped with a disconnecting device
having a contact opening of at least 3 mm. Ensure that the plug is accessible after
installation. It is strictly forbidden to use extension cords, adaptors or multiple jacks.
GREEN AND YELLOW - EARTH ---- BLUE - NEUTRAL ---- BROWN - LIVE
As the colour of the wires in the cable of this equipment may not correspond to the colour
marking in the terminals of your socket, proceed as follows:-
The GREEN and YELLOW wire must be connected to the socket terminal marked with the
letter E or with the GREEN or GREEN and YELLOW earth symbol. The BLUE wire must
be connected to the socket terminal market with the letter N or coloured BLACK or BLUE.
The BROWN wire must be connected to the socket terminal marked with the letter L or
coloured RED or BROWN.
The manufacturer cannot be held responsible for damages caused by the failure to
observe the precautions given above.
Once connections have been made, the vending machine must be placed near to a wall so that its back
has a minimum distance of 7 cm from the wall in order to allow a regular ventilation.
After having positioned the machine, adjust the four adjustable feet so that the machine is perfectly
horizontal; all the feet must be in contact with the floor.
Mount the front leg cover.
Check both the front leg cover and the mesh screens behind and under the refrigeration unit to ensure
that they are always clean and not blocked in any way.
The following instructions are valid only to the United Kingdom
The wires in the cable are coloured coded as follows:
Description of connections:
1 "Schuko" type plug
2 Differential magneto thermal switch
15
E
N
G
L
I
S
H
Tabla de contenido
loading

Tabla de contenido