GB
CONFIGURATION DIP-SWITCHES
Select the options required and perform a reset (part. 7, fig. L) to render the changes operational.
Function
n. Off On Descrption
Step-by-step
input
and
radio channel
mode (CH1)
Jolly
input mode
Preflash
Re-closure
Timer
Motor speed
Slowdown
Output US1
(multipurpose)
mode). Clean
contact
Reclosing after
the photoelectric
cells
41
Open - Stop -
During opening, upon pressing the P/P button the gate stops, pressing it again the gate closes.
Close
During closing, upon pressing the P/P button the gate stops, pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops for a few seconds and then closes.
Open - Close
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/Pbutton has no effect. During the pause, pressing the P/Pbutton has no
Always opens
effect.
"Condominium"
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
Opens-Closes
During opening, pressing the P/Pbutton has no effect. During the pause, upon pressing the P/Pbutton the
with no reversal
gate closes.
during opening
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
Clock
Closes the gate when the contact is opened and opens when the contact is closed.
SLAVE-INPUT
The control unit performs the commands received from a MASTER control unit
"Hold-to-Run"
The automation closes when the button is held down. It stops when the button is released.
Close button
The P/P button becomes a Hold-to-Run button.
Close button
Close start button. The P/P button becomes an Open Command.
The flashing light operates together with the motor.
OFF
The flashing light operates 5 seconds before any operation.
ON
After one complete opening, the control unit only closes again with a manual control.
OFF
ON
After one complete opening, the control unit closes automatically after the programmed pause time.
high
medium-high
medium-low
low
There is no slowdown in the last part of travel.
OFF
With the slowdown function connected, the motor halves its speedtowards
ON
Courtesy light
This mode enables control of a courtesy light. Lit from start of cycle to 3
contact
minutes after closing.
This contact indicates the gate status. The relay is activated at the start of opening and turns off
Dry contact
only when closing is complete.
II° Receiver
Only available if a two-channel radiocard is inserted
channel
in the pre-installed connector
This output has the function of indicator light (with different flashes to indicate door status).
Warning light
Door closed= off; in opening = slow flash; in closing= rapid flash; in pause = 2 flashes with pause;
door blocked with stop button = steady light.
OFF
Function bypassed
The activation of photoelectric cell reduces the pause time for whatever is value previously was to 2
ON
seconds.
Notes