BFT CSB-BR Manual D’instalacion Y Uso página 18

Idiomas disponibles
  • ES

Idiomas disponibles

6. DISPLAY
At power-on the board version "Br" is shown, then the fi rmware release "X.Y", then the revision "rZ"
(e.g.: fi rmware 3.4.0, br ----------> 3.4 ----------> r0) and fi nally the status.
The status code is always displayed except in programming menu.
The status code is shown on the display:
01: Idle - System just powered
02:
Opening
03:
Open limit switch reached
04:
Stopped during opening
05:
Closing
06:
Close limit switch reached
07:
Stopped during closing
08: N/A
18 -
CSB-BR
2 sec.
2 sec.
For standard working cycle, without errors, the status sequence is
->
always 2
3 when opening, 5
6.1 STATUS CODE
09:
Stopped due to photocell triggering
10:
Re-opening due to photocell triggering
11:
Photocell triggering pause time
12:
Stopped due to encoder triggering
13:
Re-opening due to encoder triggering
14:
Encoder triggering pause time
15:
Maximum working time is reached during opening
16:
Maximum working time is reached during closing
->
6 when closing
loading