BFT CSB-BR Manual D’instalacion Y Uso página 21

Idiomas disponibles
  • ES

Idiomas disponibles

02
-
: The close command acts as a release closing and safety function.
As previous setting but when closing, a detector or ptotocell activation on the close input, stops the automation. After activation
ceases, the barrier resumes closing.
dF
·
: Default
- To reset the control board to default parameters, set parameter dF=1 and exit the menu.
The following table gives the 2nd level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
TL
Maximum operating time (sec.)
Request for maintenance
Sr
(see notes after the table)
Programming maintenance
Nt
cycles in thousands
(see notes after the table)
Programming maintenance
NL
cycles in millions
(see notes after the table)
o1
Output 1
o2
Output 2
o3
Output 3
o4
Output 4
ST
Exiting the menu/saving
Description of level 2 parameters
Sr
·
: Request for maintenance
- 01: at the end of the countdown, set by counters nt and nL, one of the programmed outputs is activated (see parameter o2,o3,o4)
- 02: at the end of the countdown, set by counters nt and nL, one of the programmed outputs is activated (see parameter o2,o3,o4)
and the arm lights fl ash twice.
nt
nL
·
and
: Programming maintenance cycles in thousands and millions
The two parameters set the countdown after which a request for maintenance is signalled.
Thousands can be set with the nt parameter, millions with the nL parameter.
Example: to set 275,000 maintenance manoeuvres set nL on 0.2 and nt on 75.
The values displayed in the menu decrease along with the manoeuvres.
· Arm locking device confi guration:
To use on electromagnetic arm locking device, connect the device power supply through OUT2 or OUT3 or OUT4 and set the correspon-
ding parameter o2,o3 or o4 to 08 (see also r5 level 3).
7.3
2ND
LEVEL PROGRAMMING
03-30
00: disabled
01: active on the programmable outputs
02: active on the programmable outputs and fl ashes the arm lights twice
00-99
0.0-9.9
00: for arm lights (not modifi able)
00: request for maintenance
01: photocell triggering
02: encoder triggering
02
03: PDM contact actuated
04: arm closed
05: arm open
06: stop contact actuated
07: warning fl ash
08: arm locking electromagnetic device (see also r5 level 3)
09: open input replication
10: close input replication
11: start input replication
Pressing the "F" key, the programming menu is quit and the changes saved.
= parameter value set during installation: should be indi-
cated if DEFAULT value is modifi ed.
Settable data
15
00
00
0.0
00
05
04
02
21
CSB-BR -