8. CONTROLLED ENTRY AND AUTOMATIC EXIT
This solution is recommended when there is a single lane with bidirectional access. Entering is allowed by means of a manual command
while exiting is automatic.
ENTRY
S2
S2
EXIT
S2
S2
Loop S1 also has a safety function, not permitting the barrier to close as long as the loop is occupied.
APPROX DIMENSIONS
S2
- Connect the S1 loop receiver to the CLOSE input.
- Connect the N.O. contact of the S2 loop receiver to START input.
- The dimensional values of the loops are only approximate.
- Only use recognition systems other than remote control units (badge readers, video camera systems with license plate
recognition etc.) with a potential free output, which must be connected to the OPEN input.
Note: We suggest installing the "RME 2" metal mass detector.
PARAMETER
VALUE
Lo
02
CL
02
AS
02
S1
S1
S1
S1
S1
4000
DESCRIPTION
selects the operating logic: automatic
Close input confi guration: close-when-released input
Advanced setup: controlled entry and automatic exit
The recognition system enables bar-
rier opening.
If the coil S1 is not occupied within the
pause time, the barrier closes again.
When coil S1 is cleared, the barrier
closes immediately.
The vehicle approaches the reserved
area. When the coil S2 is occupied,
barrier opens.
If the coil S1 is not occupied within the
pause time, the barrier closes again.
When coil S1 is cleared, the barrier
closes immediately.
2000
1600
1000
2000
CSB-BR -