BFT CSB-BR Manual D’instalacion Y Uso página 22

Idiomas disponibles
  • ES

Idiomas disponibles

The following table gives the 3rd level functions and the single parameters.
= DEFAULT value set in factory.
Par
Function
Advanced setup
AS
(see notes after the table)
PD
PDM dynamic input polarity
P2
Output 2 polarity
Output 3 polarity
P3
Output 4 polarity
P4
(see notes after the table)
Advance lock-in
rs
(see notes after the table)
ST
Exiting the menu/saving
Description of level 3 parameters
AS
·
: Advanced setup
This parameter enables the use of special confi gurations to cater for specifi c necessities.
*AS=01
With this confi guration, the open command is recognised at on state, not at the signal front.
*AS=02
Controlled entry and automatic exit (see paragraph 8).
If FT=5 5 with FCA engaged and FTC blocked, the CLOSE command is stored in memory and the barrier closes back
*AS=03
when FTC is disengaged and after the time set in the Tp parameter has elapsed
If FTthe barrier closes back when FTC is disengaged and after the time set in the Tp parameter has elapsed.
P2, p3, p4
·
: Output polarity
Programmable output polarity: the outputs can be confi gured as N.O. or N.C.
Note: in the event of a power failure the contacts always open.
rS
·
: Advance lock-in
This parameter adjusts the delay between electro-lock deactivation and motor start. The delag allows for the resetting of the
residual magnetism of the electro lock.
22 -
CSB-BR
3ND
7.4
LEVEL PROGRAMMING
00: standard behaviour
01: special setup: open input works on logic state and not edge
02: special setup: controlled entry and automatic exit
03: CLOSE button storage
00: N.O.
01: N.C.
00: N.O.
01: N.C.
00: 0.5s - 01: 1s - 02: 1.5s - 03: 2s - 04: 2.5s - 05: 3s
Pressing the "F" key, the programming menu is quit and the changes saved.
= parameter value set during installation: should be indicated
if DEFAULT value is modifi ed.
Settable data
.
00
00
00
00
loading