BFT CSB-BR Manual D’instalacion Y Uso página 20

Idiomas disponibles
  • ES

Idiomas disponibles

The following table gives the 1st level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the operating logic.
Lo
(see notes after the table)
Close input confi guration
CL
(see notes after the table)
Ft
Photocells
EC
Encoder
PF
Warning fl ash
Lb
Arm lights
tP
Pause time
Resetting default parame-
dF
ters.
(see notes after the table)
ST
Exiting the menu/saving
Description of level 1 parameters
Lo
·
: Functioning logic
- 00: Hold-to-run: The automation only works when the commands are held down.
- 01: Semi automatic: The automation works with pulse commands, without automatic reclosing. Hence, when fully open, to
close you need to press the start or send the close command.
- 02: Automatic: The automation works with pulse commands. When the opening manoeuvre is completed in the standard cycle,
automatic reclosing is activated after the pause time set (parameter tP).
CL
·
: Close confi guration
01:
-
Close-when-released input
In this mode the arm closes automatically only after the vehicle has completely disengaged the photocell or the magnetic
detector (the most suitable accessories for this purpose). Connect the N.O. contact of the detector or photocell to the Close
contact terminals.
If the vehicle is over the detector or in front of the photocell, the system will not close (SAFETY).
20 -
CSB-BR
1ST
7.2
LEVEL PROGRAMMING
00: Hold-to-run
01: Semi automatic
02: Automatic
00: Standard close input
01: Close-when-released input
02: Close-when-released input and safety function.
00: When closing it stops and waits for commands past photocell deacti-
vation
01: When closing it stops; reclosing after 1'' , past photocell deactivation
02: When closing it reopens; reclosing after 1'' , past photocell deactivation
03: When closing it reopens; reclosing after 5'' , past photocell deactivation
04: When closing it reopens; reclosing as soon as the photocell deactiva-
tes
05: When closing it reopens and waits for commands, past photocell
deactivation
00: Disabled, no obstacle detection
01: When closing it stops and waits for commands
02: When closing it reopens and waits for commands
03: When closing it reopens, reclosing after 5 seconds
00: Disabled
01: Prior to each movement activates a confi gured output (see parame-
ters o2,o3,o4 in the 2nd level table)
02: Prior to each movement activates a confi gured output and the arm
lights
00: Flashing when arm is moving, off when the arm is closed and open
01: Flashing when arm is moving, on when the arm is closed and off when
the arm is open.
02: Flashing when arm is moving or closed, on when the arm is open or
arm is stopped
00-99 (expressed in seconds): Valid only with Lo=2
00: No reset
01: Reset to default parameters
Pressing the "F" key, the programming menu is quit and the changes
saved
= parameter value set during installation: should be indicated if
DEFAULT value is modifi ed.
Settable data
01
00
02
03
00
00
10
01
loading