5.4
START
N.O. input for controlling the automation according to the two step logic close -> open.
PDM INPUT
Programmable input Pd-level 3.
The signal can be repeated on programmable output
OPEN
N.O. input - opening only.
Activating this input, the automation performs the opening manoeuvre and will close only when the input is freed. Connect
clocks, daily timers or weekly timers here as needed.
CLOSE
N.O. input for closing. It allows the automation to close only if the safety devices have not triggered and if open input is
not active. Operating mode programmable with parameter CL-level -3.
FTC
N.C. safety input (photocell). Set the photocell behaviour by programming the FT-level-1 parameter. Works only during
the closing phase; it never triggers during opening.
STOP
N.C. safety input. When activated it stops the automation immediately; a subsequent start always cause opening. During
pause time (tP parameter -level -1) a stop command disables automatic reclosing, leaving the barrier open and waiting for
commands. NOTE: The door microswitch is already connected to this input and it is possible to connect other accessories,
for example the "BARRA FRATTURA" (Pushed arm), in series.
8k2
NOT CURRENTLY USED
FCA
Limit switch N.C. input in opening. When activated the opening travel fi nishes.
FCC
Limit switch N.C. input in closing. When activated the closing travel fi nishes.
ANTENNA
Antenna connection for the integrated receiver
5.5
ENCODER INPUT
The encoder may trigger an inversion only during closing, when the arm hits an obstacle. Enter the parameter
value desired by programming the EC-level-1.
In case of sensor maintenance and/or swap, reconnect respecting the shown colors.
J10
5.6
J6
ANTENNA/INPUTS TERMINAL BLOCK
J7
ENCODER TERMINAL BLOCK
UNIVERSAL PROGRAMMER CONNECTOR