Enlaces rápidos

Owner's Manual
Manual del usuariO
Parkway
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
net weight: 14.08 lBs
Peso neto:
6.39 KGs
UL-ES-Parkway-WH10
loading

Resumen de contenidos para Westinghouse Parkway-WH10

  • Página 1 UL-ES-Parkway-WH10 Owner's Manual Manual del usuariO Parkway Please write model number here for future reference: / Por favor, incluya el número del modelo aquí para futura referencia: net weight: 14.08 lBs Peso neto: 6.39 KGs...
  • Página 2 UL-ES-Parkway-WH10 safety tiPs OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT", AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED.
  • Página 3 UL-ES-Parkway-WH10 COnsejOs de seGuridad HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, MONTE EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES”, Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE PARA ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS.
  • Página 4 UL-ES-Parkway-WH10 features CaraCterístiCas VAULTED CEILING DOWNROD INSTALLATION INSTALLATION FLUSH MOUNT INSTALLATION INSTALACIÓN CON INSTALACIÓN PARA INSTALACIÓN AL RAS VARILLA VERTICAL CIELORRASOS ABOVEDADOS For low ceilings May require a longer downrod For normal ceilings (sold separately) Para cielorrasos bajos Para cielorrasos normales Podría requerir una varilla vertical más larga...
  • Página 5 UL-ES-Parkway-WH10 features CaraCterístiCas COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor, or change the style with just a flip of the blade. NOTE: Combo-Blade finishes vary, depending upon model. ASPAS DE DOBLE CARA Las aspas del rotor de doble cara presentan dos superficies con un acabado de alta calidad.
  • Página 6 UL-ES-Parkway-WH10 PreParinG fOr installatiOn antes de la instalaCión Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
  • Página 7 UL-ES-Parkway-WH10 MOuntinG BraCKet installatiOn instalaCión COn sOPOrte de MOntaje Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket and remove from the canopy.
  • Página 8 UL-ES-Parkway-WH10 MOuntinG BraCKet installatiOn MOuntinG OPtiOns instalaCión COn sOPOrte OPCiOnes de MOntaje de MOntaje Choose a MOuntinG OPtiOn elija una OPCión de MOntaje flusH MOunt OPtiOn If flush mount option is selected, proceed to page 9, step 6. OPCión de instalaCión al ras Si elige la opción de montaje al ras,...
  • Página 9 UL-ES-Parkway-WH10 flusH MOunt OPtiOn OPCión de instalaCión al ras For flush mount option, raise fan assembly and place onto hook from mounting bracket (2) into a closed hole on the canopy (1). This will allow for hands free Guide motor wires through the base of the canopy as shown and attach canopy wiring.
  • Página 10 UL-ES-Parkway-WH10 nOrMal dOwnrOd OPtiOn eXtended dOwnrOd OPtiOn OPCión COn Varilla VertiCal OPCión COn Varilla Para CielOrrasO nOrMal VertiCal MÁs larGa Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod.
  • Página 11 UL-ES-Parkway-WH10 eXtended dOwnrOd OPtiOn OPCión COn Varilla VertiCal MÁs larGa Re-install pin into extended downrod, and slide downrod ball up to the top of the downrod. Re-install set screw to secure ball to downrod. Note: Some extended downrods have a pre-drilled set-screw hole.
  • Página 12 UL-ES-Parkway-WH10 eXtended dOwnrOd OPtiOn OPCión COn Varilla VertiCal MÁs larGa Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke.
  • Página 13 UL-ES-Parkway-WH10 MOuntinG MOntaje Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge on the mounting bracket (2). This will allow for hands free wiring. With bracket holding fan assembly, make electrical connections using the Levante con cuidado el conjunto del ventilador hasta el soporte de montaje.
  • Página 14 UL-ES-Parkway-WH10 wirinG OPtiOns OPCión de CaBleadO Pull CHain wirinG OPtiOn wall COntrOl wirinG OPtiOn Follow diagram above to make wiring connections for fan pull chain control. Follow diagram above to make wiring connections for wall control operation. OPCión de CaBleadO Para Cadenilla de tirO OPCión de CaBleadO Para COntrOl de Pared...
  • Página 15 UL-ES-Parkway-WH10 seCure tO CeilinG aseGure el VentiladOr al CielOrrasO For flush mount fans, carefully lift fan from the mounting bracket, making sure not to break any wire connections. For downrod fans, slide the canopy up to the mounting bracket. Para ventiladores de instalación al ras, levante con cuidado el ventilador del soporte de montaje asegurándose de que no interrumpa ninguna conexión de los cables.
  • Página 16 UL-ES-Parkway-WH10 Blade installatiOn instalaCión de las Paletas Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided. Tighten screws securely.
  • Página 17 UL-ES-Parkway-WH10 liGHt fiXture installatiOn instalaCión del artefaCtO luMinOsO NOTE: For installation of your ceiling fan without the light kit, using the optional switch housing cap, follow step 20. If you are installing your ceiling fan with the light kit, proceed to step 21 now.
  • Página 18 UL-ES-Parkway-WH10 Install glass (1) onto light kit and tighten rubber/ metal washer (2) (rubber side facing the glass), and nut (3) onto bottom of glass. Make sure ceiling fan pull chain is threaded through the side hole in the bottom of the glass. Place decorative cap (4) over bottom of glass and secure by tightening decorative finial (5).
  • Página 19 UL-ES-Parkway-WH10 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling. Sujetar las cadenas largas de tiro con las piezas finales correspondientes, a las cadenas del ventilador, introduciendo el extremo de la cadena larga en la pieza de unión.
  • Página 20 UL-ES-Parkway-WH10 OPeratiOn and MaintenanCe Operation Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
  • Página 21 UL-ES-Parkway-WH10 OPeraCión y ManteniMientO Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
  • Página 22 UL-ES-Parkway-WH10 If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these trOuBlesHOOtinG Guide installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.
  • Página 23 UL-ES-Parkway-WH10 Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos Guía Para sOluCiOnar PrOBleMas casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar problemas.
  • Página 24 Philadelphia, PA 19154 U.S.A. Philadelphia, PA 19154 U.S.A. Westinghouse Lighting Corporation, Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee titular de la licencia de Westinghouse Electric Corporation is a registered trademark of es una marca registrada de Westinghouse Electric Corporation Westinghouse Electric Corporation...