14. Menu item: Quick start
i
Explanatory notes:
The quick start function enables users to program
the limit values for an individual torque or torque/
angle measurement with a minimum of effort.
Use the navigation keys
item "Quick start".
Confirm selection with the acknowledgement key
The following parameters must be programmed for a
torque/angle measurement:
Designation
Description
Nom. value
Target value in Nm
Tolerance
Relative value in % (counts as ± value)
Joining value
Starting value for angle measurement
Nom. Wkl
Target value in °
Tolerance
Relative value in % (counts as ± value)
14.1
Setting parameters
The navigation keys
or
ment or decrement a value
The navigation keys
or
each position (right or left).
Use the acknowledgement key
The cancel key
can be used to terminate the entry.
Robert Bosch GmbH
or
to select the menu
.
can be used to incre-
can be used to move to
to save the entries.
Menu item: Quick start | CRR 320 | 33
15. LED progress bar
Fig. 8:
LED progress bar
1) - Bi-Color LED
The LED progress bar is only active in PRESET mode.
Standard Preset measurement
Torque measurement & angle monitoring
Angle measurement & torque monitoring
en
|
0 986 629 502