Live Picture Monitoring
2) Change the setting using the INPUT
SELECTOR buttons or the Jog dial, then
register the new setting using the Shuttle dial.
Repeat steps 1) and 2) for each picture positions.
To check your settings
Move the cursor to SCREEN CHECK, then turn the
Shuttle dial clockwise. The tiled screen with the
camera combination you set is displayed.
To return to the SCREEN SET display, turn the Shuttle
dial counterclockwise.
When the settings are completed
Press the EXIT/OSD button to exit the menu.
Specifying the automatic switching
interval
You can specify the interval of the automatic switching
operation with the SEQUENCE button by setting
2. SEQUENCE of the 4. SCREEN SET menu.
1
Move the cursor to 2. SEQUENCE, then turn the
Shuttle dial clockwise.
The current setting flashes.
2
Display the desired value (1 to 30 sec.) by turning
the Jog dial clockwise, then turn the Shuttle dial
clockwise.
To specify a value for each monitor or each
camera, select INDIV., then turn the Shuttle dial
clockwise.
To specify the interval for each monitor or
each camera individually
1
When INDIV. is selected in step 2, move the
cursor to SEQUENCE SET, then turn the Shuttle
dial clockwise.
The SEQUENCE SET MENU appears.
<SEQUENCE SET MENU>
MAIN MONITOR
MAIN MONITOR SET
MON.2
MON.2 SET
QUAD
INDIVIDUAL INTERNAL SET c
24
(GB)
: 1S
c
: 1S
c
: 1S
2
Move the cursor to the item to be set, then turn the
Shuttle dial clockwise.
3
Move the cursor to the item to be set, then turn the
Shuttle dial clockwise.
MAIN MONITOR: Specify the automatic
switching interval (1 to 30 sec.) for full-screen
display of the main monitor. To specify the
value for each camera, select INDIV.
MON. 2: Specify the automatic switching interval
for full-screen display of the submonitor in the
same manner as the main monitor.
QUAD: Specify the automatic switching interval
(1 to 30 sec.) for 4-division mode.
For details about MAIN MONITOR SET and
MONITOR 2 SET, see the next paragraph.
4
When INDIV. is selected in step 3, move the
cursor to INDIVIDUAL INTERVAL SET, then
turn the Shuttle dial clockwise.
The INDIVIDUAL INTERVAL MENU appears.
<INDIVIDUAL INTERVAL MENU>
IN
IN
IN
01:1S
02:1S
03:1S
05:1S
06:1S
07:1S
09:1S
10:1S
11:1S
13:1S
14:1S
15:1S
(You can set only 01 to 09 with the HSR-X209P.)
5
Select the camera input whose switching interval is
to be set, then turn the Shuttle dial clockwise.
6
Specify the interval value using the Jog dial, then
turn the Shuttle dial clockwise.
The cursor moves to the next camera input.
7
Repeat steps 5 and 6 for each camera input.
When the settings are completed
Press the EXIT/OSD button to exit the menu.
IN
04:1S
08:1S
12:1S
16:1S