nOTE: To attach this table saw to a stand, please follow the instructions included with the
stand assembly.
Installing the Throat Plate (Fig. C)
1. Align the throat plate 
 15 
as shown in Figure C, and insert the tabs on the back of the throat
plate into the holes on the back of the table opening.
2. Rotate cam counterclockwise until the front of throat plate drops into place. Secure by
rotating cam lock knob 
 25 
clockwise 1/4 turn (when cam lock is under the table holding the
throat plate in place).
3. The throat plate includes four adjustment screws 
When properly adjusted, the front of the throat plate should be flush or slightly below the
surface of the top and secured in place. The rear of the throat plate should be flush or slightly
above the table top.
Fig. C
Removing the Throat Plate
1. Remove the throat plate 
 15 
by turning the cam lock knob 
2. Using finger hole 
 27 
on the plate, pull throat plate up and forward to expose the inside of
the saw. DO nOT operate the saw without the throat plate.

WARNING: To reduce the risk of serious personal injury, the throat plate must be locked in
place at all times.
Installing/Replacing the Blade (Fig. A, C, D)

CAUTION: Always wear gloves for handling saw blades and rough material. Saw blades
should be carried in a holder wherever practicable.
1. Raise the saw blade arbor to its maximum height by turning the blade height adjustment
wheel 
 6 
 clockwise.
2. Remove the throat plate 
 15 
.
3. Remove the arbor nut 
 28 
and clamp washer 
turning counterclockwise.
Fig. D
30
4. Place the saw blade on to the arbor 
 30 
at the front of the table 
 1 
. Assemble the clamp washer 
tighten arbor nut 
 28 
as far as possible by hand, making sure that the saw blade is against
the inner flange and the clamp washer is against the blade. Ensure the largest diameter of
the clamp washer is against the blade. Ensure the arbor and clamp washer are free from dust
and debris.
 19 
5. Use the open end of the wrench 
to keep the arbor from rotating when tightening the
arbor nut.
6. Using the other wrench, tighten the arbor nut 
nOTE: Different types of blades make different kerfs (width of cuts). Therefore, it is necessary
to check adjustment of rip scale when changing blades. Replacement blade MUST not
exceed the thickness stated on the riving knife. The riving knife provided with the saw is .087"
(2.2 mm) thick.
 15 
7. Install and lock the throat plate
.
 26 
which raise or lower the throat plate.
26
15
 25 
1/4 turn counterclockwise
 29 
from the saw arbor by
2
29
28
19
making sure the teeth of the blade 
 2 
point down
 29 
and arbor nut to the arbor and
 28 
by turning it clockwise.
Installing/Removing the Blade Guard Assembly and Riving Knife
(Fig. E)

WARNING: Use blade guard assembly for all through-cutting.
nOTE: The saw is shipped with the non-through-cutting riving knife installed.
1. Raise the saw blade arbor to its maximum height.
2. Loosen the riving knife lock knob 
3. To disengage riving knife lock pin, push lock knob toward the riving knife as indicated by the
yellow arrows on the knob.
4. While pushing the lock knob, lift the riving knife out of the clamp. Then slide the blade guard
assembly into the clamp until it bottoms out.

WARNING: Do not insert both blade guard assembly and riving knife into the clamp at the
same time.
5. Release the lock knob to engage the lock pin. Give the blade guard a slight pull upwards to
ensure pin is engaged.
6. Tighten the riving knife lock knob.
27
7. Reinstall the throat plate.
8. To remove the bladed guard assembly, follow these steps in reverse order.
nOTE: Follow the same steps above for riving knife installation.
Fig. E
25

WARNING: Before connecting the table saw to the power source or operating the saw,
always inspect the blade guard assembly and riving knife for proper alignment and clearance
with saw blade. Check alignment after each change of bevel angle.

WARNING: Confirm that the blade remains covered when the guard is lifted and released
from its highest (or deepest) cutting depth, and when beveled.
nOTE: DO NOT operate saw if riving knife lock pin is not locked into the blade guard or
riving knife.
When properly aligned, the riving knife will be in line with the blade at both table top level, and
at the top of the blade. Using a straight edge, ensure that the blade 
 21 
knife 
. Operate the blade tilt and height adjustments through the extremes of travel and
ensure the blade guard assembly clears the blade in all operations and that the anti-kickback
assembly is functioning.
Assembling the Rip Fence (Fig. F)
The rip fence can be installed in two positions on the right [position 1 for 0" to 20" (508 mm)
ripping, and position 2 for 4" (102 mm) to 24.5" (622 mm) ripping and one position on the left of
your table saw.
1. Align the locator pins 
 32 
on the fence rails with the slots 
2. Place fence onto the rail as shown in Figure F maintaining pin and slot alignment on both
ends of the fence.
3. Secure the rip fence by snapping down the latches 
and rear latches in place.
 31 
(minimum of three turns).
11
31
2
 2 
is aligned with the riving
 33 
on each fence end.
 17 
to the rails. Be sure to snap both front
English
21
5
loading

Este manual también es adecuado para:

Dwe7485