Hilti VC 150-6 XE Manual De Instrucciones página 14

Ocultar thumbs Ver también para VC 150-6 XE:
Idiomas disponibles

Idiomas disponibles

3. Open the two catches.
4. Lift the vacuum cleaner top section away from the waste material container and place it on a level surface.
5. Check the cut-out contacts and clean them with a brush if necessary (if dirty).
6. Check the seal at the vacuum cleaner top section and clean it with a cloth if necessary.
7. Fit the vacuum cleaner top section onto the waste material container and close the two catches.
7.5 Checks after cleaning and maintenance
1. After cleaning or carrying out maintenance, check that the vacuum cleaner is assembled correctly and
that it functions faultlessly.
2. Test each of the functions.
7.6 Transport
Do not carry the appliance when it is full of waste material.
The appliance may not be lifted directly by crane.
▶ Remove the power conditioner (if applicable) or loose accessory tools from the holder.
▶ Empty the appliance before carrying it to another location.
▶ Do not tip the appliance or transport it lying on its side after using it to pick up liquids.
▶ Use the tapered adapter to connect both ends of the hose together conveniently for transport.
7.7 Storage
▶ Store the vacuum cleaner in a secure, dry place where it is inaccessible to unauthorized users.
8 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
8.1 Troubleshooting
Trouble or fault
No suction power or reduced
suction power.
Dust is blown out of the appli-
ance.
The appliance switches it-
self off or on inadvertently or
static electricity discharges
through the user.
The appliance doesn't start or
switches itself off after a short
time.
The motor doesn't restart.
10
English
Printed: 22.02.2017 | Doc-Nr: PUB / 5334126 / 000 / 00
Possible cause
The dust bag is full.
The filter element is clogged with
dirt or dust.
The suction hose or dust hood on
the electric tool is blocked.
The filter element is not fitted cor-
rectly.
The filter element is damaged.
Electrostatic charge is not
conducted away – the
appliance is connected to an
unearthed/ungrounded power
outlet.
The water level cut-out is acti-
vated.
The mains circuit breaker has been
tripped.
The waste material container is full. ▶ Switch the appliance off and
Action to be taken
▶ Change the dust bag.
▶ If the automatic filter cleaning
system is deactivated, activate
it and allow the vacuum cleaner
to run for 30 seconds.
▶ Clean the suction hose and the
dust hood.
▶ Fit the filter element again
correctly.
▶ Fit a new filter element.
▶ Connect the appliance to an
earthed/grounded power outlet
and use an antistatic suction
hose.
▶ Clean the sensors and the
area around the sensors with a
brush.
▶ Reset the circuit breaker.
▶ Find the reason for the overload
current if the circuit breaker
trips again.
empty the waste material
container.
loading

Este manual también es adecuado para:

Vc 150-6 xVc 150-10 xVc 150-10 xe