12.8. Refilling the grease cup with pump grease

When the grease cup is empty, fill both grease cups with grease.
a. Remove the grease cup by turning it counterclockwise.
b. Refill with pump grease until the grease cup top.
Use lithium-based general purpose grease no. 3 or equivalent.
c. Install the grease cup and tighten it until the grease cup upper surface and the knob cover upper part are at the same level.

12.9. Cooling vanes maintenance

Inspect visually the cooling vanes through the cover. If they are clogged or damaged, contact an authorized technical assistance to
have them cleaned, replaced or fixed.
Left side
Right side
Grease cup
Cooling vanes
Grease cup
Grease
121/127