Dometic CFX28L Instrucciones De Uso página 23

Nevera por compresor
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
CFX28 – CFX65DZ
7.13
Replacing the AC fuse
D
DANGER! Danger of electrocution!
Disconnect the power supply and the connection cable before you
replace the device fuse.
➤ Disconnect the power supply to the device.
➤ Pull off the connection cable.
➤ Pry out the fuse insert (fig. 4 2, page 3) with a screwdriver.
➤ Replace the defective glass fuse with a new one that has the same type and rating
(4 A, 250 V).
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
7.14
Replacing the DC plug fuse
➤ Unscrew the contact pin housing (fig. 9 3, page 5) from the plug (fig. 9 1,
page 5).
➤ Replace the defective fuse (fig. 9 2, page 5) with a new fuse of the same type
and rating (3AG, Fast Acting, 10 A).
➤ Re-assemble the plug in reverse order.
7.15
Replacing the light PCB
➤ Disconnect the power supply to the device.
➤ Pry out the transparent cover with a screwdriver (fig. 0 1, page 5).
➤ Unscrew the PCB mounting screws (fig. 0 2, page 5).
➤ Pull out the plug from the PCB (fig. 0 3, page 5).
➤ Replace the defective light PCB with a new one.
➤ Fit new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.
➤ Reconnect the power supply to the device.
EN
Operation
23