ESAB EM 215ic Instrucciones De Uso página 19

Ocultar thumbs Ver también para EM 215ic:
Idiomas disponibles

Idiomas disponibles

4 INSTALLATION
1.
Rating plate with supply connection data
4.3.1
Recommended fuse sizes and minimum cable area
WARNING!
An electrical shock or fire hazard is probable if the following electrical service
guide recommendations are not followed. These recommendations are for a
dedicated branch circuit sized for the rated output and duty cycle of the welding
power source.
Supply voltage
Input current at maximum output
Maximum recommended fuse* or circuit breaker rating
*Time delay fuse UL class RK5, refer to UL 248
Maximum recommended fuse* or circuit breaker rating
*Normal operating UL class K5, refer to UL 248
Minimum recommended cord size
Maximum recommended extension cord length
Minimum recommended grounding conductor size
Supply from power generators
The power source can be supplied from different types of generators. However, some
generators may not provide sufficient power for the welding power source to operate
correctly. Generators with Automatic Voltage Regulation (AVR) or with equivalent or better
type of regulation, with 8 kW rated power, are recommended.
0463 407 001
120 – 230 V, 1 ~ 50/60 Hz
230 V AC
30 A
30 A
50 A
12 AWG (4 mm
50 ft (15 m)
12 AWG (4 mm
- 19 -
120 V AC
30 A
30 A
50 A
2
2
) 12 AWG (4 mm
)
25 ft (8 m)
2
2
) 12 AWG (4 mm
)
© ESAB AB 2017