Correction of Malfunctions
Problem
Cause
The sprayer does
The sprayer is not plugged in.
not start.
The sprayer was turned off while still under
pressure.
No voltage is coming from the wall plug.
The extension cord is damaged or has too low
a capacity.
Device overheated
There is a problem with the motor.
The spray device
The unit will not prime properly or has lost
runs but does not
prime.
suck up any paint
The paint bucket is empty or the suction tube
when the selector
is not totally immersed in the paint.
switch is set to the
The suction tube is clogged.
PRIME position.
The inlet filter is clogged.
The suction tube is loose at the inlet valve.
The inlet valve or outlet valve is stuck.
The inlet valve is worn or damaged.
The PRIME/SPRAY valve is plugged
The sprayer draws
The spray nozzle is worn.
up paint but the
The inlet filter is clogged.
pressure drops
The spray nozzle is blocked (if fitted)
when the gun is
The paint is too viscous or contaminated.
triggered.
The inlet valve is worn or damaged.
The spray gun leaks
Internal parts of the gun are worn or dirty.
The nozzle
The nozzle was assembled incorrectly.
assembly leaks
A seal is dirty.
The spray gun will
The spray nozzle is plugged.
not spray.
The spray nozzle is blocked (if fitted)
The spray tip is in the reverse position.
The paint pattern is
The paint is too viscous or contaminated.
tailing.
The spray nozzle is plugged.
The spray nozzle is worn.
The spray nozzle is blocked (if fitted)
The inlet filter is clogged.
The inlet valve is worn or damaged.
CE Declaration of Conformity
We declare under sole responsibility that this product conforms to the following relevant stipulations:
2006/42/EC, 2014/30/EU, 2011/65/EU, 2012/19/EU
Applied harmonised norms:
EN ISO 12100, EN 1953, EN 62841-1, EN 55014-1, EN 55014-2, EN IEC 61000-3-2, EN 61000-3-3, EN 62233
The EU declaration of conformity is enclosed with the product.
If required, it can be re-ordered using order number 2373934.
28
Control Pro 250 M / 275 M
Remedy
Plug the sprayer in.
Perform pressure relief procedure and set selector
switch back to SPRAY
Properly test the power supply voltage.
Replace the extension cord.
Switch the device off, turn the selector switch to the
PRIME position (vertical), remove the mains plug
and allow device to cool down for min. 30 minutes.
Eliminate the cause of overheating, e.g. covered
ventilation slot.
Please contact Wagner Service
Try to prime the unit again.
Refill the bucket or immerse the suction tube in paint.
Clean the suction tube.
Clean the inlet filter.
Tighten it securely.
Follow the instructions in the chapter "Help with
suction problems".
Replace
Please contact Wagner Service
Replace the spray nozzle with a new nozzle.
Clean the inlet filter.
Clean or replace the filter.
Thin or strain the paint.
Replace
Please contact Wagner Service
Check the tip assembly and assemble properly
Clean the seal.
Clean the spray nozzle and use the HEA filter set.
Clean or replace the filter.
Put the nozzle in the forward position.
Thin or strain the paint.
Clean the spray nozzle and use the HEA filter set.
Replace the spray nozzle with a new nozzle.
Clean or replace the filter.
Clean the inlet filter.
Replace
loading