6.2 Connections on the WTC 200
K
Fig. 14: WTC 200 connections
Connection
Description
A
• Additional connections when installing the WTX 200extension
B
• Mini USB connection (without function)
C
• Network connection RJ45 (10/100 MBit) with status LEDs
• Network connection for communicating with the server and Dialock software 2.0.
R
• Holder for Micro SD card
E
• Holder for SIM card (without function)
F
• Pins for clipping on the WTX 200 extension
G
• Removable cover
H
• RS485 connections (terminals 8, 9, 10)
• Max. 2 readers possible on an RS485 connection
• Max. 4 readers on the controller can be managed with the Dialock software
• Lead length max. 200 m
• Connection of readers (A to A; B to B) and extensions
• Power supply of extensions max. 0.5 A;
• Voltage supply of the extensions: voltage applied to terminal 1 (pos. 11) minus
approx. 1 V
I
• Relay output ports (terminals 6 and 7) 30 V / 2 A
• Lead length max. 25 m
• For example: Connection of electric strikes (depending on electric strike: NO and C
or NC and C), external signal generators (NO and C)
J
• Analogue input ports (terminals 2-5)
• Lead length max. 25 m
• For example: Connection of door signalling contacts
K
• Connection of external power supply (terminal 1) 12 V - 24 V DC
F
A
B
J
I
C
D
E
F
G
H