4.4 Installation conditions WTC 200

Component
WTC 200
top hat rail
On-site power supply
Power supply unit

4.5 Installation conditions WTX 200

Component
WTX 200

4.6 WTX 201 installation conditions

Component
WTX 201
Top hat rail
78
Mounting condition
• The ambient conditions must be observed
(
3.4 Technical data WTC 200, page 74")
• Connection leads for connecting the various components are
available.
• A top hat rail of type "TS 35" according to EN 50022 is available
and installed.
• There is a separate electric circuit for WTC 200 installation.
• The voltage of the on-site power supply complies with the
requirements of the power supply unit used
see power supply unit operating instructions
• Cable thickness = 2.5 mm
The controller can be connected to any power supply unit that meets
the following requirements:
• 12 V - 24 V DC output voltage
• Output: in accordance with the configuration of the system
(min. 11 W)
• If the external power supply unit has a capacity of over 15 VA,
installation on a top hat rail poses a risk of fire. Install the power
supply unit with more than 15 VA power in a separate sheet steel
housing.
Mounting condition
• The ambient conditions must be observed. (
WTX 200, page 75)
• The connection leads for connecting the various components are
available.
• The jumpers are positioned in accordance with the required
installation version.
Mounting condition
• The ambient conditions must be observed. (
WTX 201, page 75)
• The connection leads for connecting the various components are
available.
• A top hat rail of type "TS 35" according to EN 50022 is available
and installed.

3.6 Technical data

3.7 Technical data