EN
5e. Measures
1
1
Measures: Adjustment of set points and measuring
probes.
2
Set points for each measurement.
5f. pH probe calibration
Always begin the calibration procedure with a calibration reset.
1
1
pH probe calibration: Recommended once a
month during the pool season.
2
Calibration using buffer solutions (liquids models
pH7 / pH10 / neutral). Follow the instructions that
appear on screen 3.
5g. Rx probe calibration
Always begin the calibration procedure with a calibration reset.
1
1
Redox probe calibration: Recommended every
two months during the pool season.
2
Calibration with buffer solutions. With reference
solution 465 mV. Follow the instructions that appear
on screen 3.
2
3
3
Setting the set points using the Up/Down arrows.
2
3
Calibration procedure involving 7 steps.
4
Manual calibration: Allows you to set the probes
to 1 point (without buffer solution) – recommended
only for adjusting small deviations in readings.
2
3
Calibration procedure involving 4 steps.
4
Manual calibration: Allows you to set the probes to
1 point (without solution) – recommended only for
adjusting small deviations in readings.
AquaRite
®
Pro Touch
Only use spare parts supplied by Hayward brands ®
3
3
5
Page 13 on 16
4
5
Without removing the probe from the water, use
the Up/Down arrows to adjust the reading to your
reference value (photometer or other measuring
instrument).
4
Without removing the probe from the water, use
the Up/Down arrows to adjust the reading to your
reference value (photometer or other measuring
instrument).
5
5