3b. Wall-mounted installation
Mount the control box on the wall. The box must be installed in the equipment room (dry, temperate, ventilated). Caution,
acid vapours can cause irreversible damage to your device. Position the treatment product tanks accordingly.
Unplug the pool filter pump before you begin the installation. The installation must be performed in compliance with the
regulations in effect in the country of installation.
®
The AquaRite
Pro Touch must be fitted a minimum horizontal distance of 3.5 m (or more, if required by local regulations)
from the pool, within 1 m of a protected outlet and within 4.5 m of the planned cell location.
The box must be placed vertically on a flat surface, with the cables downwards. As this box is also used to evacuate heat
(heat dissipation from internal components), it is important that the four sides of the box remain unobstructed. Do not install
®
the AquaRite
Pro Touch behind a panel or in an enclosed space.
Before installing the control box in the intended location, check that the power cord can reach the protected outlet and that
the cell cable can reach the intended cell location.
The flow switch must be installed on the return pipe directly in line with and upstream of the cell and the treatment product
injection point. Allow a 25 cm straight section before the flow switch. A hole should previously have been drilled in the pipe
to allow the flow switch to pass through. Screw the flow switch into the saddle clamp, taking care to seal with Teflon. Then
install the clamp on the pipe. The flow switch must be installed in the direction of operation to ensure that it is tripped by the
flow from the filtration pump.
All the metal components of the swimming pool can be connected to the same earth as per local regulations.