3c. Installation of pH and ORP probes, and acid dosing pump
The pH and ORP probes are «wet» packed and protected by a plastic cap. The probes must always remain
wet. If the probes are allowed to dry, they will be permanently unusable (not covered by the warranty) and
the pH-ORP test kit will be ineffective.
Remove the pH and ORP probes from their plastic protective caps and set the caps aside for later use
(wintering). Insert the probes into the double probe holder and tighten to ensure they are watertight. Connect
the probe holder to the valves screwed onto the saddle clamps and tighten by hand only. Check that the
probes are watertight at startup. Seal with Teflon, if required.
After installation, check that the probes are constantly in contact with the water in the pool. When the filtration
pump is not running (even for long periods), the water remaining in the chamber may be sufficient to protect
the probes.
The product (acid, etc.) injection device must be installed last on the water return line, after any equipment
(heater, cell, etc.). A hole should previously have been drilled in the pipe to allow the treatment product to
pass through. Install the saddle clamp and screw the injection valve into the saddle clamp using the adapter
provided. Seal with Teflon.
Use the transparent PVC hose for suction (between the acid tank and the peristaltic pump) and the semi-
rigid white polyethylene tube for injection (between the peristaltic pump and the injection valve).
For the ORP option, install the ORP card in the RX slot on the motherboard.
3d. Electrical installation and wiring
®
Connect the AquaRite
•
: This circuit must be protected by a residual current device
(RCD) (residual current: 30 mA max.)
and a 16A time-delay circuit-breaker.
Connecting inputs:
Name
Description
FL1
Flow switch
Cover
Closed cover detection
pH
Peristaltic pump
°C/°F
Temperature probe (not supplied)
Pro Touch to a permanent power outlet.
ORP chip
pH Chip
(Rx)
(pH)
AquaRite
®
Only use spare parts supplied by Hayward brands ®
ORP
probe
Pro Touch
Page 7 on 16
Remove the white lid by unscrewing
the 6 screws using a screwdriver.
A
B
C
D
G
Temperature
H
probe
I
E
F
pH
probe
Terminals Type of input/output
A - C
Dry contact
A - D
Dry contact
E - F
230 V
G - H - I
Red, Yellow, Black
O
R
P
Rx probe
p
H
pH probe
Peristaltic
pump
Détecteur
de débit
Closed cover
Flow
detection
switch
pH
Peristaltic
pump
voltage output