USER MANUAL
EN
8 - FIRST DAYS OF MAINTENANCE
The pool will require particular attention during the 10-15 days of use. Particular points for attention are as follows:
Make sure the pH remains on the ideal level (7.2 - 7.5). If the pH is unusually unstable and uses a lot of acid check the alkalinity
1
(recommended levels between 80 y 120 ppm).
The pool must be vacuumed and the skimmers cleaned whenever necessary to ensure perfect water conditions.
2
REMEMBER that the system requires a certain amount of time to adapt to your swimming pool and will require additional chemicals during the first 3-5 days.
CLEANING THE TITANIUM CELL
If necessary carry out a visual inspection of the cell monthly. To clean it:
Remove the cell from its support (after turning off the filtration system and closing off the necessary valves).
1
2
Place the cell for no more than 10 minutes in 15% hydrochloric acid (1.5 l of acid for each 8.5 l of water).
3
Once the scale has softened rinse the cell with a hose.
DO NOT USE METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it
vulnerable to chemicals, deteriorate the cell and cancel the guarantee.
FORTNIGHTLY CHECKS
MONTHLY CHECKS
FREE CHLORINE:
1.0 - 2.0 PPM
TOTAL ALKALINITY (TAC) pH:
PH:
7.2 - 7.5
SALT CONCENTRATION:
GENERAL MAINTENANCE
The pool must be vacuumed as usual and the skimmers emptied whenever necessary.
1
FILTER BACKWASHING: The system requires only occasional filter backwashing; once every 20 days should be sufficient (providing
2
the filter pressure does not exceed 1 bar, in which case a backwash may be necessary).
VERY IMPORTANT: Make sure the cell is off while cleaning the filter. To do so, disconnect the flow switch of the cell (thin cable)
while cleaning the filter.
ADDING NEW WATER: Always through the skimmers so that the new water passes through Neosal system before entering the pool.
3
Remember to add the necessary salt (5-6 gr) per added liter of water.
In winter changing the pool water is not recommendable. We recommend that the system runs 2-3 times per week (2-3 hours per day).
4
TROUBLESHOOTING
ES
BLANK DISPLAY
• Check if ON/OFF switch is illuminated.
• Check the connection wire between display and motherboard.
• Check the fuse of the device (3.15 A) – it could have tripped due to overload.
• Check the power supply 110V/60Hz – 230V/50Hz.
• If the problem persists contact TECHNICAL SERVICE
ELECTROLYSIS DOES NOT REACH MAXIMUM INTENSITY
• Check sodium bromide or common salt concentration in water.
• Check cell status (may be scaled up or calcified).
• Clean the cell according to the instructions in section 5.
• Clean the flow detector situated in the cell housing.
• Check titanium cell is not worn out (remember that the cell is guaranteed
for 5 000 hours, approx. 2-3 years of summer usage).
12
80 - 120 PPM
CYANURIC ACID:
30 - 50 ppm
4 000 - 6 000 ppm
TITANIUM CELL:
Visual inspection to detect scale.
EXCESS OF CHLORINE IN THE WATER
• Lower electrolysis cell intensity and/or reduce filtration hours.
TITANIUM CELL INCRUSTED IN LESS THAN 1 MONTH
• Very hard waters with a high pH and total alkalinity: balance water adjusting
pH and total alkalinity.
• Check to ensure the system automatically changes polarity every
300 minutes approximately.
• Consult with our technical service to consider accelerating the polarity
change (auto-cleaning). WARNING: Accelerating the polarity change
decreases the cell life (5 000 hours) proportionally.
Use only genuine replacement parts Hayward
USER MANUAL
EN
FREE CHLORINE LEVELS DON'T REACH 0,8 PPM
• Increase filtration interval.
• Increase electrolysis level.
• Check levels of sodium bromide or common salt in the pool (5-6 gr NaCl/l).
• Check level of isocyanuric acid in pool (30-50 ppm), only if using common salt.
• Check if reactive agents in test kit has expired.
• Check if the temperature or amount of users has risen.
• If the water pH is above 7.8 it must be adjusted.
ELECTROLYSIS DISPLAY SHOWS LOW
• Water lacks conductivity (see section 3 - Initial water adjustments).
• Check for scale on cell.
• See section 6 - Electrolysis does not reach maximum intensity.
ELECTROLYSIS DISPLAY SHOWS FLOW
• Check flow detector cable.
• Clean scale on flow detector at the top of cell housing.
• Check if system is free of air (probe must always be submerged).
POLARITY 1 REACHES MAXIMUM INTENSITY, BUT POLARITY 2 (AUTO CLEAN) DOES NOT REACH MAXIMUM INTENSITY
• If salt level is correct (5-6 kg/m 3 ): Cell is reaching its end of life. As of this moment check intensity every 15-30 days.
• When polarity 2 does not reach medium intensity, we recommend substituting the cell for a new one if it happens during the summer period.
If it happens during winter, change the cell before the next summer period.
WARNING
Keep chemical levels in pool as instructed in this manual.
CLEANING FILTER
Make sure the cell is off while cleaning the filter. To do so, disconnect the flow switch of the cell (thin cable) while cleaning the filter.
VERY IMPORTANT
Remember that the system requires a certain amount of time to adapt to your swimming pool and will require additional chemicals during the first 3-5 days.
EARTHING
All metallic components in the pool such as lamps, ladders, heat exchangers, drains or similar elements within 3 m from the pool (10 feet)
must be connected to an earth below 37 Ohms. If using heat exchangers, we recommend them to be made of titanium.
SECURITY
To avoid accidents, children should not handle this product unless supervised by an adult. Children should be supervised at all times
when in or near a spa, pool or jacuzzi.
HANDLING AND DOSING DANGEROUS CHEMICALS
Chemicals should be handled with extreme precaution. When preparing acid, always add acid to water, never add water to acid, because very
dangerous gasses may be produced.
13
Revb _ 2022
WHITE FLAKES IN THE WATER
• The water is excessively hard and it is unbalanced.
• Balance the water and check the cell, proceeding to clean it if necessary.
• Put 1 small bag of flocculant in the skimmer and recirculate 24 hours.
WHITE FLAKES IN THE WATER
• Metallic elements lack standardized earth connection.
Contact an electrician to solve the problem.
• Metallic components are not stainless steel
(minimum 304 – recommended 316).
Use only genuine replacement parts Hayward