PROBLEM
The thermal
overload protector
cuts out repeatedly.
The air receiver
pressure drops
when the
compressor shuts
off.
There is excessive
moisture in the
discharge air.
The compressor
continuously runs.
The air output is
lower than normal.
TROUBLESHOOTING
POSSIBLE CAUSE
There is low voltage from the
power source.
There is a lack of proper
ventilation, or the room
temperature is too high.
The wrong gauge wire or
length of extension cord is
being used.
The connections (fittings,
tubing, etc.) are loose and
leaking.
The drain valve is loose or
open.
The check valve is leaking.
There is excessive water in
the air tank.
The compressor is working
under a high humidity
environment.
The pressure switch is
defective.
An excessive amount of air
is being used.
The inlet valves are broken.
The connections (fittings,
tubing, etc.) are loose and
leaking.
15 - ENG
SOLUTION
Call an electrician.
Move the compressor to a
well-ventilated area.
Check for proper gauge wire
and cord length.
Check all connections with a
soap and water solution and
tighten.
Tighten the drain valve.
Bring the compressor to a
service center.
Drain the tank.
Move the compressor to an
area of less humidity; use an
air line filter.
Bring the compressor to a
service center.
Decrease the air usage;
the compressor is not
large enough for the tool's
requirement.
Bring the compressor to a
service center.
Tighten the connections.