Note: Troubleshooting problems may have similar causes and solutions.
PROBLEM
The compressor
does not run.
The motor hums
while running
slowly, or it doesn't
run at all.
The fuses blow or
circuit breaker trips
repeatedly.
TROUBLESHOOTING
POSSIBLE CAUSE
There is a loss of power or
the motor is overheated.
There is no power to the
unit.
The circuit breaker has
tripped or a fuse has blown
at the main power source.
The thermal overload
protector is actuated.
The pressure switch is bad.
The compressor has reached
automatic shutoff pressure.
There is low voltage from the
power source.
The wrong gauge wire or
length of extension cord is
being used.
There is a shorted or open
motor wiring.
There is a defective check
valve or unloader.
The incorrect fuse type is
being used.
The wrong gauge wire or
length of extension cord is
used.
There is a defective check
valve or unloader.
14- ENG
SOLUTION
Check for proper use of
extension cord.
Check to be sure the unit is
plugged in.
Check the fuse/breaker.
Turn the air compressor OFF
( O ).
Unplug air compressor and
wait until compressor cools
down.
Plug the air compressor into
an approved outlet.
Turn the air compressor ON
( I ).
Bring the compressor to a
service center.
Release the air from the tank
until the compressor restarts
automatically.
Call an electrician.
Check for proper gauge wire
and cord length.
Bring the compressor to a
service center.
Bring the compressor to a
service center.
Check for the proper fuse.
Use a time-delay fuse.
Disconnect other electrical
appliances from the circuit or
operate the compressor on its
own branch circuit.
Check for the proper gauge
wire and cord length.
Bring the compressor to a
service center.