Expansion modules
Element
1
2
3
5.3
Arming device (e.g. NBS 10) and associated system
components
4
Element
1
2
3
4
5
6
7
8
9
10
5.4
Line-fed glass break detector
4
Bosch Sicherheitssysteme GmbH
Description
Intrusion line with terminal resistance (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Contact line without terminal resistance
Intrusion line with double terminal resistance (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Refer to graphic 8 in chapter Graphics, page 4.
Description
Incoming and outgoing LSNs, can be exchanged.
4
Route the cable shield both ways for loop formation.
Cable shield (wire color: white / green and brown / green)
Blocklock display LED1 "BLL" (wire color: 11 = red, 12 = pink)
Blocklock display LED2 "BLA" (wire color: 13 = green, 14 = gray)
Blocklock magnet "BSM" (wire color: 17 = yellow, 18 = blue / red)
Blocklock for tamper detector zone (wire color: 49 = white, 50 = brown)
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
E.g. coded arming device
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Blocklock for primary line (wire color : 39 = black, 40 = blue)
Resistors (EOL 1 and EOL 2):
EOL 1 = 3k92 and EOL 2 = 12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
EOL 1 and EOL 2 = 4k7 for ISP-EMIL-3RDP
E.g. door contact
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
E.g. bolt contact
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Refer to graphic 9 in chapter Graphics, page 4.