Bosch ISP-EMIL-120 Manual De Instalación página 26

Ocultar thumbs Ver también para ISP-EMIL-120:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
26
en | Technical data
No.
51/52
53/54
55/56
57/58
59/60
7
Technical data
Electrical
Minimum operating voltage in VDC (LSN part) 15
Maximum operating voltage in VDC (LSN
part)
Minimum operating voltage in VDC (other
functions)
Maximum operating voltage in VDC (other
functions)
Maximum current consumption in mA (LSN
part)
Maximum current consumption in mA (other
functions at 12 V)
Maximum current consumption in mA (other
functions at 28 V)
Minimum current consumption in mA (other
functions at 28 V)
Connection options
Primary lines PL 1 - PL 6
Connection options
2017.09 | 04 | F.01U.076.548
Connections
Features
SP
Not connected, designed for external resistor (EOL):
PL 6
SP
Not connected, designed for external resistor (EOL):
WT
Connection of optional wall tamper contact. If the wall
tamper contact is not connected, the WT bridge (57 + 58)
remains plugged in.
SP
Spare, connected internally
Installation Manual
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
12k1 for ISP-EMIL-3RDP in case of line-fed glass break
detectors
Primary line for connection of detector zone 6
Connection of line-fed glass break detectors
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
12k1 for ISP-EMIL-3RDP in case of line-fed glass break
detectors
33
9
30
4.95
370
180
20
6 detector zones can be programmed as
holdup, intrusion, tamper or bolt
Expansion modules
Bosch Sicherheitssysteme GmbH
loading

Este manual también es adecuado para:

Isp-pcba-emilIsp-emil-3rdp