INSTALLATION & OPERATION
Power Supply Connections
Ground Wire Connection
Voltage Set to 230 Volts
Voltage Set to 115 Volts
PUMP CAPACITIES
MOTOR
MODEL
HP
FP4512
1/2
FP4542
FP4532
1
FP4562
1
*Time delay fuse or circuit breakers are recommended in any motor circuit.
FP1002 (02-01-2023)
Pressure Switch
NAMEPLATE
VOLTS
BRANCH FUSE
AMPS
RATING* AMP
12.4/6.2
115/230
18.6/9.3
115/230
14.8/7.4
115/230
WIRING YOUR PUMP
Ensure pump circuit breaker is OFF and pump is
disconnected from power before servicing or handling pump.
1.
Remove the cover from the pressure switch.
2.
Connect the bare copper ground to the ground screw in the
pressure switch.
3.
Connect the power supply to the terminals marked "From
Line" in the diagram below.
Ground
Connections
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
(0 - 30)
20/15
12/14
10/14 (5.5/2)
20/15
12/14(3/2)
18/14(8.4/2)
20/15
12/14(3/2)
8/14(8.4/2)
To Motor
From Line
201 - 300
(31 - 61)
(62 - 91)
AWG WIRE SIZE (MM²)
8/14(8.4/2)
6/14(14/2)
6/14(14/2)
5907 1108
301 - 400
(92 - 122)
6/12(14/3)
6/12(14/3)
6/12(14/3)
5