f. The appliance must not be used in laundry rooms.
g. Only install the appliance in dry rooms.
h. The appliance must not be started in the presence of dangerous materials, vapours or
liquids.
i. Clean the air filters at least once a week.
2.3 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the appliance, make sure that:
• The voltage and power frequency values match those specified on
the appliance plate data.
• The power supply line is equipped with an efficient ground connection
and that it is correctly dimensioned for the maximum absorption of
the appliance.
• The appliance's power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• The appliance is powered solely through a socket compatible with the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia Splendid
technical support or by similarly qualified personnel.
3 - WATER UNLOADING
3.1 - EMPTYING THE TANK
•
When the led
(7).
• Remove the tank (7) from the appliance body working with both hands (Fig.7).
• Empty the tank (Fig. 8).
• Correctly reposition the tank (7) in the appliance body, otherwise the led
the appliance doesn't work.
3.2 - CONTINUOUS WATER UNLOADING
•
If desired, it is possible to connect the supplied hose (14) to the connection (13) to continuously drain water
collected by dehumidification.
• Switch off the appliance and disconnect the plug from the power socket.
• Remove the cover (T) from the connection (13) (Fig. 9).
• Connect the supplied rubber hose (14) to the fitting (13).
• It is advised to fix the hose (14) to the connection (13) using a clamp (not supplied).
In "Laundry" mode it is advisable to drain water continuously so that the dehumidifier
doesn't stop if the tank is full.
Make sure the rubber hose (14) doesn't exceed the exhaust joint height, otherwise
water will remain in the appliance and could cause a malfunction, damage it and/or
cause dangerous work conditions.
During operation with continuous unloading, do not remove the water tank.
Possible problems caused by the external water drain are not detected by the full tank
alarm.
An efficient supervision is necessary in order to prevent malfunctions, damages to
the appliance and/or dangerous work conditions.
switches on, the appliance stops, the buzzer rings and it is necessary to empty the tank
remains turned on and