6.3.2.4 Consulting software versions and configuration
Allows you to consult:
- the tank-pump combination (Model) selected for the installation,
- the software versions for the control box's motherboard and the
screen card. This may be necessary in case of maintenance or interven-
tion on the enclosure.
SC_2VX
Logs
MODEL: the model of the station connected to the box as set at the time
of commissioning. If it does not match, see
to change the model.
screen
- HW: the hardware version for the motherboard and the display board.
- SW: the software version for the motherboard and for the display
board.
• Press
to return to the main menu.
This information cannot be changed.
6.3.3 Settings Menu
SC_2VX
你好
Hello
Bonjour
Ciao HALLO
LA
HO
6.3.3.1 Setting the date
The date setting is particularly important for alarm management and
maintenance monitoring.
SC_2VX
Settings
Date
• Then press
and
to select the value.
• Then press
and
to switch from day to month and month to
year.
• Press
to confirm the choice.
• Press
to return to the main menu.
6.3.3.2 Setting the hour
The hour setting is imporant for alarm management.
SC_2VX
Settings
Hour
• Then press
and
to select the value.
• Then press
and
to switch from hour to minute and minute to
second.
• Press
to confirm the choice.
A sensor being activated:
- is white on the display
- has a value of 1.
SC_2VX
Logs>Version
Model: SANICUBIC 2 VX BLDC
Motherboard
Screenboard
HW:
2.2
2.2
SW:
3.3.0
3.7.1
10.1 Return to the start-up
Allows you to:
- set the date and time,
- adjust the brightness of the
display, activate/deactivate the
audible alarm,
- set the pump delay time,
- set the delay time for the aux-
iliary pump to start,
- select the frequency of mainte-
nance,
- set the BMS parameters
SC_2VX
Settings>Date
P1
P2
SFA
SC_2VX
Settings>Hour
P1
P2
• Press
to return to the main menu.
6.3.3.3 Various
SC_2VX
Settings
Various
Brightness adjustment
Allows you to adjust the brightness of the display during use.
SC_2VX
Settings>Various
• Press
and
to select the value.
• Press
to confirm the choice.
• Press
to return to the main menu.
Enable/disable audible alarm
Selects whether the alarm notification (display of an alarm window) is
accompanied by an audible signal.
SC_2VX
Settings>Various
• Press
and
to choose between «Enable» or «Disable».
• Press
to confirm the choice.
• Press
to return to the main menu.
6.3.3.4 Setting the Stop delay time
The stop delay time is an additional pumping time when the pump's
stop level has been reached. It allows the tank to be emptied as much
as possible and optimises the pumping of surface matter.
SC_2VX
Settings
Stop delay
- Mode: This pump stop delay can be managed manually («Manual»)
or automatically («Automatic») depending on the station configured at
commissioning and the duration of the last pumping times (for more
details see
10.3 Learning loops
- Duration: In Manual mode, you can enter a time delay value between 0
and 120 seconds, in increments of 1 s.
• Press
and
to choose between «Manual» and «Automatic».
• Press
and
to switch from Mode to Duration.
• Press
and
to choose the duration.
• Press
to confirm the choice.
• Press
to return to the main menu.
Note:
- If the automatic management mode has been chosen, the "Duration"
parameter cannot be modified.
- If Sanipump SLD was selected, the value is 0 s and cannot be changed.
6.3.3.5 Setting the start of the auxiliary pump
When one of the pumps is running continuously, the second pump is
activated after the time set in this menu to support the first pump. This
activation of the auxiliary pump corresponds to an abnormal case (e.g.
a hydraulic problem on the 1st pump) and will cause the automatic de-
activation of the 1st pump.
To be relevant, the set time must be at least twice the duration of a
normal ON-OFF cycle.
22
Then press
and
through the submenus. Confirm
with
to enter the submenu.
SC_2VX
Settings>Various
SC_2VX
Settings>Various
SC_2VX
Settings>Stop delay
Mode: Manual
Duration: 2s
).
to scroll