Loading the Tool
Connect the air supply to the tool.
Open tail jaws which grip the mandrel, by:
70510-01000 Bench Mounted Guard: Push the guard away from the operator.
Screw selected nose jaws onto barrel of the tool.
Insert a mandrel into the tail end of the fasteners through the paper pod.
Slide the mandrel follower spring onto the mandrel ensuring correct orientation, as shown in the accessories manual
(part number 07900-09508).
Gripping the tail end of the mandrel, tear off the paper pod from around the fasteners.
Open the nose jaws either by rotating the outer ring on Cam operated jaws or by pushing outwards on the jaw ends, as
illustrated below left.
Insert the previously assembled mandrel, mandrel follower spring and fasteners into the nose jaws until the first
fastener to be placed is protruding from the nose jaw.
Close the nose jaws and adjust so that the first fastener protrudes by 1.5mm - 3mm (1/16" to 1/8"), as shown in the
illustration below right.
Close the tail jaws to ensure the mandrel is gripped, by:
70510-01000 Bench Mounted Guard: Pull the guard towards the operator.
Reloading the Tool
Open tail jaws of tool.
Open the nose jaws and pull the empty mandrel and mandrel follower spring out of the tool.
Reload the tool by following the above instructions, starting at stage .

4.8 OPERATING PROCEDURE

You must check that the cursor orientation and the nose equipment are correct before attempting to operate the tool.
Push the fastener, protruding from the nose jaws, fully into the application holes ensuring that the application is held
square.
Operate the foot pedal without releasing - the mandrel head is pulled through the fastener, forming the fastener into
the application.
Remove the application.
Release the foot pedal. The next fastener will be automatically presented through the nose jaws, ready for placing.

4.9 PLACING EQUIPMENT

All nose equipment, mandrels, follower springs and other accessories can be found in the accessories manual (part number