Proper Hand Position; Tool Operation; Servicing The Tool; Maintenance Frequency - Stanley NeoBolt PB2500N Manual De Instrucciones

Ocultar thumbs Ver también para NeoBolt PB2500N:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

E N G L I S H
WARNING: To reduce the risk of serious personal injury, ALWAYS hold securely in anticipation of a
sudden reaction.

4.1 PROPER HAND POSITION

Proper hand position requires one hand on the main Handle (G). (Fig. 1a)

4.2 TOOL OPERATION

Installing a NeoBolt® fastener (Fig. 5 & 6)
Place NeoBolt® Pin (CC) in work piece (Fig. 5a)
Thread Collar (DD) onto NeoBolt® Pin (Fig. 5a, 5b) and snug up to work piece.
Place Collet (A) over end of NeoBolt® Pin (CC) (Fig. 5b)
Pull and hold the Switch (H) until installation is complete (Fig. 5c).
When the NeoBolt® has been installed completely, release the Switch (H). The tool will return to its initial
position automatically.
If you release the Switch (H) before the end of the setting stroke, the tool will immediately return to its initial
position. If the NeoBolt® has not been set completely, repeat the previous steps.
Reset function (Fig. 1)
If the tool does not move to its initial position after releasing the Switch (H) or stops during the installation
stroke, reset the tool to home by moving the Forward/Reverse bar (J) to the reverse position.
To select reverse, depress the forward/reverse control button on the left side of the tool. Pull the Switch
(H) until the Collet (A) returns to the home position and releases the fastener.
If this does not resolve the issue, remove the battery, re-insert and then repeat the prior step. If the issue
persists, contact your local service representative.
To select installation mode (forward rotation), release the trigger switch and depress the forward/reverse
control button on the right side of the tool.
NOTE: The center position of the control button locks the tool in the off position. When changing the position
of the control button, be sure the trigger is released.

5. SERVICING THE TOOL

5.1 MAINTENANCE FREQUENCY

Item
General Tool Inspection
Clean & lubricate Nose Equipment
Check Anvil and Collet for wear or damange
Clean & lubricate Pulling Head & Ball Screw Assembly
*Recommend contacting authorized service centre
NOTICE: The charger and battery pack are not serviceable.
Recommended lubricants: Molykote G-4700, Sumiplex MP no2, or equivelant.
NOTICE: DO NOT use lubricants with Graphite or MoS2 additives when servicing the Pulling Head and Ball
Screw Assembly

5.2 CLEANING

ALWAYS wear approved eye protection at all times when cleaning equipment
16
Frequency
Daily
Daily or 5,000 installations
10,000 installations
50,000 installations*
Tabla de contenido
loading

Tabla de contenido