Technical Data; Ambient Conditions; Detection Range/Measuring Range; Electrical Data - Balluff BTL BNC 00 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL BNC 00 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
BTL BNC_ 00- _ _ _ _ -C12NL_ _0-000S04 / BTL ZNC_ 00- _ _ _ _ -C12NL_ _0-000S04
Magnetostrictive Linear Position Sensor – Rod Style
9

Technical data

The specifications are typical values for
BTL BNC_ 00- _ _ _ _ -C12NL_ _0-000S04 and
BTL ZNC_ 00- _ _ _ _ -C12NL_ _0-000S04 at 24 V DC,
room temperature and a measuring length of 500 mm in
conjunction with the BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R or BTL-P-1014-2R magnet.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Operating pressure
Maximum pressure
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
2), 3)
Protection per IEC 60529 (when
threaded together)
9.2

Detection range/Measuring range

Measuring length
Resolution
Repeat accuracy
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Non-linearity
Detectable speed
www.balluff.com
9.3
Operating voltage Ub
Current draw (at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to
(GND – Housing)
9.4
Short circuit protection
Reverse polarity protection
−40...+85 °C
−40...+100 °C
9.5
≤ 90%, non-
IO-Link version
condensing
Transmission rate
≤ 450 bar
750 bar
Cycle time
(10 × 1 min)
Data format
≤ 30 ppm/K
Error value
100 g/6 ms
Measuring length 500 mm, magnet in the middle of the measuring range
1)
50 g/2 ms
Individual specifications as per Balluff standard
2)
Resonant frequencies excluded
3)
12 g,
10...2000 Hz
IP67, IP69K
25...4000 mm
5 µm
≤ ±10 µm
1000 Hz
500 Hz
250 Hz
± 50 μm
≤ 10 m/s

Electrical data

18...30 V DC
≤ 60 mA
≤ 1.5 W
Ub up to 36 V DC
500 V DC

Electrical Connection

Signal output to GND
and to 30 V DC
Ub up to 30 V DC

Interface

1.1
COM2 (38.4 kBaud),
COM3 (230.4 kBaud)
≥ 1 ms
32 Bit signed
0x7FFFFFFC
english
15
Tabla de contenido
loading

Este manual también es adecuado para:

Btl znc 00 serie

Tabla de contenido